Datasheet
TLV2460-Q1, TLV2461-Q1, TLV2462-Q1, TLV2463-Q1, TLV2464-Q1
TLV2460A-Q1, TLV2461A-Q1, TLV2462A-Q1, TLV2463A-Q1, TLV2464A-Q1
www.ti.com
SGLS008E –MARCH 2003–REVISED OCTOBER 2012
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
V
DD
Supply voltage
(2)
6 V
V
ID
Differential input voltage range –0.2 V to V
DD
+ 0.2 V
I
I
Input current (any input) ±200 mA
I
O
Output current ±175 mA
I
I
Total input current (into V
DD+
) 175 mA
I
O
Total output current (out of GND) 175 mA
T
A
Operating free-air temperature range –40°C to 125°C
T
J
Maximum junction temperature 150°C
D (8 pin) 176°C/W
D (14 pin) 123°C/W
θ
JA
Thermal impedance, junction to ambient
(3)
PW (8 pin) 259°C/W
PW (14 pin) 174°C/W
DGK (8 pin) 242°C/W
T
stg
Storage temperature range –65°C to 150°C
Latch-Up performance meets 100 mA per AEC-Q100 (Class I) Class I
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential voltages, are with respect to GND.
(3) Package thermal impedance is calculated in accordance with JESD 51-5.
RECOMMENDED OPERATING CONDITIONS
MIN MAX UNIT
Single supply 2.7 6
V
DD
Supply voltage V
Split supply ±1.35 ±3
V
ICR
Common-mode input voltage range –0.2 V
DD
+ 0.2 V
T
A
Operating free-air temperature –40 125 °C
V
IH
2
Shutdown on/off voltage level
(1)
V
V
IL
0.7
(1) Relative to voltage on the GND terminal of the device
Copyright © 2003–2012, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: TLV2460-Q1 TLV2461-Q1 TLV2462-Q1 TLV2463-Q1 TLV2464-Q1 TLV2460A-Q1 TLV2461A-
Q1 TLV2462A-Q1 TLV2463A-Q1 TLV2464A-Q1