Datasheet

 
      
    
SLAS251A − DECEMBER 1999 − REVISED JANUARY 2003
15
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
conversion cycles (continued)
CS
CSTART
SDI
INT
EOC
SDO
Hi-Z
Select/Read
Cycle
Select/Read
Cycle
t
(sample
)
t
(conv)
Previous Conversion
Result
Previous Conversion
Result
FS
Hi-Z Hi-Z
Device Going Into
Extended Sampling Mode
Device Get Out
Extended Sampling
Mode
Read
Cycle
Normal
Cycle
This is one of the single shot commands. Conversion starts on next rising edge of CSTART
.
Figure 9. Mode 00 Single Shot/Extended Sampling (FS Signal Used, FS Pin Connected to TMS320 DSP)
modes using the FIFO: modes 01, 10, 11 timing
CS
CSTART
SDI
INT
SDO
Hi-Z
From Channel 2
FS
§
‡‡‡ §
Hi-Z
Configure Select
Conversion #1
Select
Conversion #4
Read FIFO #1 #2 #3 #4
Top of FIFO
From Channel 2
Command = Configure write for mode 01, FIFO threshold = 1/2
Command = Read FIFO, 1st FIFO read
§
Command = Select ch2.
Use any channel select command to trigger SDI input.
Figure 10. TLV1504/TLV1508 Mode 01 DSP Serial Interface (Conversions Triggered by FS)