Datasheet
SLAS148 − SEPTEMBER 1996
7
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
POST OFFICE BOX 1443
• HOUSTON, TEXAS 77251−1443
operating characteristics V
CC
= V
ref
= 3.3 V, f
(CLK)
= 250 kHz, t
r
= t
f
= 20 ns, T
A
= 25°C (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
†
MIN TYP MAX UNIT
Supply-voltage variation error V
CC
= 3 V to 3.6 V ±1/16 ±1/4 LSB
Total unadjusted error (see Note 5)
V
ref
= 3.3 V,
T
A
= MIN to MAX
±1 LSB
Common-mode error Differential mode ±1/16 ±1/4 LSB
t
pd
Propagation delay time,
output data after CLK↑
MSB-first data
C
L
= 100 pF
200 500
ns
t
pd
output data after CLK↑
(see Note 6)
LSB-first data
C
L
= 100 pF
80 200
ns
t
dis
Output disable time, DO after CS↑
C
L
= 10 pF, R
L
= 10 kΩ 80 125
ns
t
dis
Output disable time, DO after CS↑
C
L
= 100 pF, R
L
= 2 kΩ
250
ns
t
conv
Conversion time (multiplexer-addressing
time not included)
8
clock
periods
†
All parameters are measured under open-loop conditions with zero common-mode input voltage. For conditions shown as MIN or MAX, use the
appropriate value specified under recommended operating conditions.
NOTES: 5. Total unadjusted error includes offset, full-scale, linearity, and multiplexer errors.
6. The MSB-first data is output directly from the comparator and, therefore, requires additional delay to allow for comparator response
time. LSB-first data applies only to TLV0832.