BLOCK DIAGRAM
2:1
MUX
PRBS
Generator
10 Bit
Registers
TD(0-9)
PRBSEN
LOOPEN
Parallel to
Serial
Phase Generator
Clock
REFCLK
Control
Logic
MODESEL
ENABLE
TESTEN
Interpolator
and
Clock Extraction
PRBS
Verification
Serial to Parallel
and
Comma Detect
Clock
RBC1
RBC0
SYNC/PASS
RD(0-9)
SYNCEN
RBCMODE
JTAG
Control
Register
JTMS
JTRSTN
JTDI
TCK
JTDO
2:1
MUX
2:1
MUX
Clock
Data
TXP
TXN
RXP
RXN
LOS
TLK1201ARCP , TLK1201AIRCP
ETHERNET TRANSCEIVERS
SLLS580D – FEBRUARY 2004 – REVISED SEPTEMBER 2007
Terminal Functions
TERMINAL
I/O DESCRIPTION
NAME NO.
SIGNAL
MODESEL 15 I Mode select. This terminal selects between the 10-bit interface and a reduced 5-bit DDR
P/D
(1)
interface. When low, the 10-bit interface (TBI) is selected. When pulled high, the 5-bit DDR mode
is selected. The default mode is the TBI.
LOS 26 O Loss of signal. Indicates a loss of signal on the high-speed differential inputs RXP and RXN.
If the magnitude of RXP-RXN > 150 mV, then LOS = 1 which is a valid input signal.
If the magnitude of RXP-RXN > 50 mV and < 150 mV, then LOS is undefined.
If the magnitude of RXP-RXN < 50 mV, then LOS = 0 which is a loss of signal.
RBCMODE 32 I Receive clock mode select. When RBCMODE and MODESEL are low, half-rate clocks are output
P/D
(1)
on RBC0 and RBC1. When MODESEL is low and RBCMODE is high, a full baud-rate clock is
output on RBC0 and RBC1 is held low. When MODESEL is high, RBCMODE is ignored and a full
baud-rate clock is output on RBC0 and RBC1 is held low.
RBC0 31 O Receive byte clock. RBC0 and RBC1 are recovered clocks used for synchronizing the 10-bit
RBC1 30 output data on RD0 – RD9. The operation of these clocks is dependent upon the receive clock
mode selected.
In the half-rate mode, the 10-bit output data words are valid on the rising edges of RBC0 and
RBC1. These clocks are adjusted to half-word boundaries in conjunction with synchronous
detect. The clocks are always expanded during data realignment and never slivered or truncated.
RBC0 registers bytes 1 and 3 of received data. RBC1 registers bytes 0 and 2 of received data.
In the normal rate mode, only RBC0 is valid and operates at 1/10th the serial data rate. Data is
aligned to the rising edge.
In the DDR mode, only RBC0 is valid and operates at 1/10th the serial data rate. Data is aligned
on both the rising and falling edges.
(1) P/D = Internal pulldown
Copyright © 2004 – 2007, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): TLK1201ARCP TLK1201AIRCP