TX_CLK
TX_EN
TXD
PMD Output Pair
t
1
TX_CLK
TX_EN
PMD Output Pair
0 0
1 1
PMD Output Pair
t
1
t
2
TLK100
www.ti.com
SLLS931BAUGUST 2009REVISED DECEMBER 2009
Table 9-13. 10BASE-T Transmit Timing (Start of Packet)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
(1)
t
1
Transmit Output Delay from the Falling Edge of TX_CLK 10 Mb/s MII mode 5.8 bits
(1) (1) 1 bit time = 100ns in 10Mb/s.
Figure 9-13. 10BASE-T Transmit Timing (Start of Packet)
Table 9-14. 10BASE-T Transmit Timing (End of Packet)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
t
1
End of Packet High Time (with 0’ ending bit) 250 310 ns
t
2
End of Packet High Time (with 1’ ending bit) 250 310 ns
Figure 9-14. 10BASE-T Transmit Timing (End of Packet)