Datasheet

TLE2161, TLE2161A, TLE2161B
EXCALIBUR JFET-INPUT HIGH-OUTPUT-DRIVE
µPOWER OPERATIONAL AMPLIFIERS
SLOS049D – NOVEMBER 1989 – REVISED MAY 1996
12
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics at specified free-air temperature, V
CC ±
= ± 5 V (unless otherwise noted)
PARAMETER TEST CONDITIONS
T
A
TLE2161M
TLE2161AM
TLE2161BM
UNIT
MIN TYP MAX
TLE2161M
25°C 0.8 3.1
TLE2161M
Full range 6
V
IO
In
p
ut offset voltage
TLE2161AM
25°C 0.6 2.6
mV
V
IO
Inp
u
t
offset
v
oltage
TLE2161AM
Full range 4.6
mV
TLE2161BM
25°C 0.5 1.9
TLE2161BM
Full range 3.1
α
VIO
Temperature coefficient of input offset
voltage
V
IC
= 0, R
S
= 50
Full range 6 µV/°C
Input offset voltage long-term drift
(see Note 4)
25°C 0.04 µV/mo
I
IO
In
p
ut offset current
25°C 1 pA
I
IO
Inp
u
t
offset
c
u
rrent
Full range 15 nA
I
IB
In
p
ut bias current
25°C 3 pA
I
IB
Inp
u
t
bias
c
u
rrent
Full range 30 nA
V
ICR
Common mode in
p
ut voltage range
25°C
1.6
to 4
–2
to 6
V
V
ICR
Common
-
mode
inp
u
t
v
oltage
range
Full range
1.6
to 4
V
All
p
ackages
R
L
=10k
25°C 3.5 3.7
V
All
packages
R
L
=
10
k
Full range 3
V
V
OM
Maximum positive peak FK and JG
R
L
= 600
25°C 2.5 3.6
V
OM +
output voltage swing packages
R
L
=
600
Full range 2
V
D and P
R
L
= 100
25°C 2.5 3.1
V
packages
R
L
=
100
Full range 2
All
p
ackages
R
L
=10k
25°C 3.7 3.9
All
packages
R
L
=
10
k
Full range –3
V
OM
Maximum negative peak FK and JG
R
L
= 600
25°C 2.5 3.5
V
V
OM –
g
output voltage swing packages
R
L
=
600
Full range –2
V
D and P
R
L
= 100
25°C 2.5 2.7
packages
R
L
=
100
Full range –2
All
p
ackages
V
0
=±28V
R
L
=10k
25°C 15 80
All
packages
V
0
=
±2
.
8
V
,
R
L
=
10
k
Full range 2
V
0
= 0 to 2 5 V
R
L
= 600
25°C 1 65
FK and JG
V
0
=
0
to
2
.
5
V
,
R
L
=
600
Full range 0.5
A
VD
Large-signal differential
packages
V
0
=0to 25V
R
L
= 600
25°C 1 16
V/mV
A
VD
gg
voltage amplification
V
0
=
0
to
2
.
5
V
,
R
L
=
600
Full range 0.5
V/mV
V
0
=0to2V
R
L
= 100
25°C 0.75 45
D and P
V
0
=
0
to
2
V
,
R
L
=
100
Full range 0.5
packages
V
0
=0to 2V
R
L
= 100
25°C 0.5 3
V
0
=
0
to
2
V
,
R
L
=
100
Full range 0.25
Full range is – 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at T
A
= 150°C extrapolated
to T
A
= 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.