Datasheet

  
  
µ  
SLOS193B − FEBRUARY 1997 − REVISED MAY 2004
56
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
TYPICAL CHARACTERISTICS
Figure 40
UNITY-GAIN BANDWIDTH
vs
FREE-AIR TEMPERATURE
R
L
= 10 k
C
L
= 100 pF
See Figure 3
V
CC±
= ±5 V
V
CC±
= ±15 V
T
A
− Free-Air Temperature − °C
1251007550250−25−50−75
1
1.5
2
2.5
− Unity-Gain Bandwidth − MHz
B
1
Figure 41
PHASE MARGIN
vs
SUPPLY VOLTAGE
R
L
= 10 k
C
L
= 100 pF
T
A
= 25°C
See Figure 3
62°
61°
60°
59°
58°
57°
56°
0
| V
CC±
| − Supply Voltage − V
2 4 6 8 101214161820
55°
− Phase Margin
m
φ
Figure 42
PHASE MARGIN
vs
LOAD CAPACITANCE
C
L
− Load Capacitance − pF
10008006004002000
10°
20°
30°
40°
50°
0°
60°
See Figure 3
T
A
= 25°C
R
L
= 10 k
V
CC±
= ±15 V
− Phase Margin
m
φ
Figure 43
PHASE MARGIN
vs
FREE-AIR TEMPERATURE
− Phase Margin
m
φ
1251007550250−25−50−75
T
A
− Free-Air Temperature − °C
54°
56°
58°
60°
62°
64°
66°
V
CC±
= ±5 V
V
CC±
= ±15 V
See Figure 3
C
L
= 100 pF
R
L
= 10 k
Data at high and low temperatures are applicable only within the rated operating free-air temperature ranges of the various devices.