Datasheet

TLE202x, TLE202xA, TLE202xB, TLE202xY
EXCALIBUR HIGH-SPEED LOW-POWER PRECISION
OPERATIONAL AMPLIFIERS
SLOS191D FEBRUARY 1997 REVISED NOVEMBER 2010
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
21
TLE2021 electrical characteristics at specified free-air temperature, V
CC
= 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
T
TLE2021M TLE2021BM
UNIT
PARAMETER TEST CONDITIONS
T
A
MIN TYP MAX MIN TYP MAX
UNIT
V
Input offset voltage
25°C 120 600 80 200
V
V
IO
Input offset voltage
Full range 1100 300
μV
α
VIO
Temperature coefficient of
input offset voltage
Full range 2 2 μV/°C
Input offset voltage long-term drift (see Note 4)
V
I
C
= 0, R
S
= 50 Ω
25°C
0.005 0.005 μV/mo
I
Input offset current
V
IC
= 0
,
R
S
= 50 Ω
25°C 0.2 6 0.2 6
nA
I
IO
Input offset current
Full range 10 10
nA
I
Input bias current
25°C 25 70 25 70
nA
I
IB
Input bias current
Full range 90 90
nA
V
Common-mode input
R 50 Ω
25°C
0
to
3.5
0.3
to
4
0
to
3.5
0.3
to
4
V
V
ICR
Common mode input
voltage range
R
S
= 50 Ω
Full range
0
to
3.2
0
to
3.2
V
V
High level output voltage
25°C 4 4.3 4 4.3
V
V
OH
High-level output voltage
R 10 kΩ
Full range 3.8 3.8
V
V
Low level output voltage
R
L
= 10 kΩ
25°C 0.7 0.8 0.7 0.8
V
V
OL
Low-level output voltage
Full range 0.95 0.95
V
A
Large-signal differential
V 1 4 V to 4 V
R 10 kΩ
25°C 0.3 1.5 0.3 1.5
V/ V
A
VD
Large signal differential
voltage amplification
V
O
= 1.4 V to 4 V, R
L
= 10 kΩ
Full range
0.1 0.1
V/μV
CMRR
Common mode rejection ratio
V V min
R 50 Ω
25°C 85 110 85 110
dB
CMRR Common-mode rejection ratio V
IC
= V
ICR
min, R
S
= 50 Ω
Full range
80 80
dB
k
Supply-voltage rejection ratio
V 5 V to 30 V
25°C 105 120 105 120
dB
k
SVR
Supply voltage rejection ratio
(ΔV
CC
±
/ΔV
IO
)
V
CC
= 5 V to 30 V
Full range 100 100
dB
I
Supply current
25°C 170 230 170 230
A
I
CC
Supply current
V
O
= 2 5 V
No load
Full range 230 230
μA
ΔI
CC
Supply current change over
operating temperature range
V
O
=
2
.5
V
,
N
o
l
oa
d
Full range 9 9 μA
Full range is 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at T
A
= 150°C extrapolated to T
A
= 25°C using the Arrhenius equation
and assuming an activation energy of 0.96 eV.