Datasheet

TLC59213
TLC59213A
SLVS867A MAY 2009REVISED MARCH 2010
www.ti.com
ELECTRICAL CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
I
CEX
Output leakage current V
CC
= 13.2 V, Outputs off 2 µA
I
OUT
= –350 mA 2.35
V
CE(sus)
Output saturation voltage I
OUT
= –225 mA 2.15 V
I
OUT
= –100 mA 1.96
I
I
Input current V
CC
= 13.2 V, V
I
= 0 or 13.2 V 1 µA
V
f
Clamp forward voltage I
f
= –350 mA –2 V
All outputs OFF 4.6 13
V
CC
= 13.2 V,
I
CC
Supply current mA
V
I
= 0 or 13.2 V
All outputs ON 4.8 13
C
I
Input capacitance 10 pF
TIMING REQUIREMENTS
over recommended operating free-air temperature range (unless otherwise noted), see Figure 3
PARAMETER TEST CONDITIONS MIN MAX UNIT
D before CLK 50 ns
t
su
Setup time
CLR high before CLK 50 ns
TLC59213,
T
A
= -40°C to 85°C 50
TLC59213A
TLC59213 T
A
= 0°C to 70°C 25
t
h
Hold time D after CLK ns
T
A
= 0°C to 70°C, V
CC
= 4.5 V to 5.5 V 15
TLC59213A
T
A
= 0°C to 70°C, V
CC
= 10.8 V to 13.2 V 19
t
w
Pulse width CLK, CLR 100 ns
SWITCHING CHARACTERISTICS
over operating free-air temperature range (unless otherwise noted), see Figure 3
T
A
= 25°C T
A
= –40°C to 85°C
FROM TO TEST
PARAMETER UNIT
(INPUT) (OUTPUT) CONDITIONS
MIN TYP MAX MIN MAX
Propagation delay time, RL = 25 ,
t
PLH
CLK Y 107 200 250 ns
low-to-high level output C
L
= 15 pF
t
PHL
CLK Y 111 200 250
Propagation delay time, RL = 25 ,
ns
high-to-low level output C
L
= 15 pF
t
PHLR
CLR Y 104 200 250
4 Submit Documentation Feedback Copyright © 2009–2010, Texas Instruments Incorporated
Product Folder Link(s): TLC59213 TLC59213A