Datasheet
TLC555, TLC555Y
LinCMOS TIMERS
SLFS043C – SEPTEMBER 1983 – REVISED SEPTEMBER 1997
9
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
operating characteristics, V
DD
= 5 V, T
A
= 25°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS MIN TYP MAX UNIT
Initial error of timing interval
‡
V
DD
= 5 V to 15 V, R
A
= R
B
= 1 kΩ to 100 kΩ,
1% 3%
Supply voltage sensistivity of timing interval
DD
,
C
T
= 0.1 µF,
AB
,
See Note 3
0.1 0.5 %/V
t
r
Output pulse rise time
R
L
=10MΩ
C
L
=10
p
F
20 75
ns
t
f
Output pulse fall time
R
L
=
10
MΩ
,
C
L
=
10
pF
15 60
ns
f
max
Maximum frequency in astable mode
R
A
= 470 Ω,
C
T
= 200 pF,
R
B
= 200 Ω,
See Note 3
1.2 2.1 MHz
‡
Timing interval error is defined as the difference between the measured value and the average value of a random sample from each process
run.
NOTE 3: R
A
, R
B
, and C
T
are as defined in Figure 1.
electrical characteristics at V
DD
= 5 V, T
A
= 25°C
PARAMETER
TEST CONDITIONS MIN TYP MAX UNIT
V
IT
Threshold voltage 2.8 3.3 3.8 V
I
IT
Threshold current 10 pA
V
I(TRIG)
Trigger voltage 1.36 1.66 1.96 V
I
I(TRIG)
Trigger current 10 pA
V
I(RESET)
Reset voltage 0.4 1.1 1.5 V
I
I(RESET)
Reset current 10 pA
Control voltage (open circuit) as a percentage of supply voltage 66.7%
Discharge switch on-state voltage I
OL
= 10 mA 0.14 0.5 V
Discharge switch off-state current 0.1 nA
V
OH
High-level output voltage I
OH
= – 1 mA 4.1 4.8 V
I
OL
= 8 mA 0.21 0.4
V
OL
Low-level output voltage
I
OL
= 5 mA 0.13 0.3
V
I
OL
= 3.2 mA 0.08 0.3
I
DD
Supply current See Note 2 170 350 µA