POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics at specified free-air temperature, V
DD
= 15 V
PARAMETER
TEST
T
A
TLC555C TLC555I TLC555M
PARAMETER
CONDITIONS
T
A
MIN TYP MAX MIN TYP MAX MIN TYP MAX
V
IT
Threshold voltage
25°C 9.45 10 10.55 9.45 10 10.55 9.45 10 10.55
V
IT
Threshold
voltage
Full range 9.35 10.65 9.35 10.65 9.35 10.65
I
IT
Threshold current
25°C 10 10 10
p
I
IT
Threshold
current
MAX 75 150 5000
V
I(TRIG)
Trigger voltage
25°C 4.65 5 5.35 4.65 5 5.35 4.65 5 5.35
V
I(TRIG)
Trigger
voltage
Full range 4.55 5.45 4.55 5.45 4.55 5.45
I
I(TRIG)
Trigger current
25°C 10 10 10
p
I
I(TRIG)
Trigger
current
MAX 75 150 5000
V
I(RESET)
Reset voltage
25°C 0.4 1.1 1.5 0.4 1.1 1.5 0.4 1.1 1.5
V
I(RESET)
Reset
voltage
Full range 0.3 1.8 0.3 1.8 0.3 1.8
I
I(RESET)
Reset current
25°C 10 10 10
p
I
I(RESET)
Reset
current
MAX 75 150 5000
Control voltage (open
circuit) as a
percentage of supply
voltage
MAX 66.7% 66.7% 66.7%
Discharge switch
I
OL
= 100 mA
25°C 0.77 1.7 0.77 1.7 0.77 1.7
g
on-state voltage
I
OL
=
100
mA
Full range 1.8 1.8 1.8
Discharge switch
25°C 0.1 0.1 0.1
g
off-state current
MAX 0.5 120 120
I
OH
=10mA
25°C 12.5 14.2 12.5 14.2 12.5 14.2
I
OH
= –
10
mA
Full range 12.5 12.5 12.5
V
OH
High-level output
I
OH
=5mA
25°C 13.5 14.6 13.5 14.6 13.5 14.6
V
OH
g
voltage
I
OH
= –
5
mA
Full range 13.5 13.5 13.5
I
OH
=1mA
25°C 14.2 14.9 14.2 14.9 14.2 14.9
I
OH
= –
1
mA
Full range 14.2 14.2 14.2
I
OL
= 100 mA
25°C 1.28 3.2 1.28 3.2 1.28 3.2
I
OL
=
100
mA
Full range 3.6 3.7 3.8
V
OL
Low-level output
I
OL
=50mA
25°C 0.63 1 0.63 1 0.63 1
V
OL
voltage
I
OL
=
50
mA
Full range 1.3 1.4 1.5
I
OL
=10mA
25°C 0.12 0.3 0.12 0.3 0.12 0.3
I
OL
=
10
mA
Full range 0.4 0.4 0.45
I
DD
Su
pp
ly current
See Note 2
25°C 360 600 360 600 360 600
I
DD
Supply
current
See
Note
2
Full range 800 900 1000
Full range is 0°C to 70°C for TLC555C, – 40°C to 85°C for TLC555I, and – 55°C to 125°C for TLC555M. For conditions shown as MAX, use the
appropriate value specified in the recommended operating conditions table.
NOTE 2: These values apply for the expected operating configurations in which THRES is connected directly to DISCH or TRIG.