Datasheet


 
SLFS043F − SEPTEMBER 1983 − REVISED FEBRUARY 2005
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics at specified free-air temperature, V
DD
= 2 V for TLC555C, V
DD
= 3 V for
TLC555I
PARAMETER
TEST
T
A
TLC555C TLC555I
PARAMETER
TEST
CONDITIONS
T
A
MIN TYP MAX MIN TYP MAX
V
IT
Threshold voltage
25°C 0.95 1.33 1.65 1.6 2.4
V
IT
Threshold voltage
Full range 0.85 1.75 1.5 2.5
V
I
IT
Threshold current
25°C 10 10
I
IT
Threshold current
MAX 75 150
pA
V
I(TRIG)
Trigger voltage
25°C 0.4 0.67 0.95 0.71 1 1.29
V
I(TRIG)
Trigger voltage
Full range 0.3 1.05 0.61 1.39
V
I
I(TRIG)
Trigger current
25°C 10 10
I
I(TRIG)
Trigger current
MAX 75 150
pA
V
I(RESET)
Reset voltage
25°C 0.4 1.1 1.5 0.4 1.1 1.5
V
I(RESET)
Reset voltage
Full range 0.3 2 0.3 1.8
V
I
I(RESET)
Reset current
25°C 10 10
I
I(RESET)
Reset current
MAX 75 150
pA
Control voltage (open circuit) as
a percentage of supply voltage
MAX 66.7% 66.7%
Discharge switch on-stage
I
OL
= 1 mA
25°C 0.03 0.2 0.03 0.2
Discharge switch on-stage
voltage
I
OL
= 1 mA
Full range 0.25 0.375
V
Discharge switch off-stage
25°C 0.1 0.1
Discharge switch off-stage
current
MAX 0.5 120
nA
V
OH
High-level output voltage
I
OH
= −300 A
25°C 1.5 1.9 2.5 2.85
V
OH
High-level output voltage I
OH
= −300 µA
Full range 1.5 2.5
V
V
OL
Low-level output voltage
I
OL
= 1 mA
25°C 0.07 0.3 0.07 0.3
V
OL
Low-level output voltage I
OL
= 1 mA
Full range 0.35 0.4
V
I
DD
Supply current
See Note 2
25°C 250 250
I
DD
Supply current
See Note 2
Full range 400 500
µ
Full range is 0°C to 70°C for the TLC555C and −40°C to 85°C for the TLC555I. For conditions shown as MAX, use the appropriate value specified
in the recommended operating conditions table.
NOTE 2: These values apply for the expected operating configurations in which THRES is connected directly to DISCH or to TRIG.