Datasheet
SLAS105D − JANUARY 1995 − REVISED APRIL 2004
www.ti.com
4
recommended operating conditions
MIN NOM MAX UNIT
V
DDA
−AGND 4.75 5 5.25
V
Supply voltage
V
DDD
−AGND 4.75 5 5.25
V
Supply voltage
AGND−DGND −100 0 100 mV
Reference input voltage (top), V
I(REFT)
V
I(REFB)
+1.8 V
I(REFB)
+2 V
DDA
V
Reference input voltage (bottom), V
I(REFB)
0 0.6 V
I(REFT)
−1.8 V
Analog input voltage range, V
I(ANLG)
(see Note 1) V
I(REFB)
V
I(REFT)
V
Full scale voltage, V
I(REFT)
− V
I(REFB)
1.8 5 V
High-level input voltage, V
IH
4 V
Low-level input voltage, V
IL
1 V
Pulse duration, clock high, t
w(H)
12.5 ns
Pulse duration, clock low, t
w(L)
12.5 ns
Operating free-air temperature, T
A
TLC5540C 0 70 °C
Operating free-air temperature, T
A
TLC5540I −40 85 °C
(1)
1.8 V ≤ V
I(REFT)
− V
I(REFB)
< V
DD