Datasheet

TLC3544, TLC3548
5-V ANALOG, 3-/5-V DIGITAL, 14-BIT, 200-KSPS, 4-/8-CHANNELS SERIAL
ANALOG-TO-DIGITAL CONVERTERS WITH 0-5 V (PSEUDODIFFERENTIAL) INPUTS
SLAS266C OCTOBER 2000 REVISED MAY 2003
23
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
operation cycle timing (continued)
Table 3. Operation Options
CONVERSION IS INITIATED BY
MODE
CS FS CSTART
00 1. Issue new Select/Read operation to
read data and start new conversion.
2. Reconfigure the device.
1. Issue new Select/Read operation to
read data and start new conversion.
2. Reconfigure the device.
1. Issue new CSTART to start next
conversion; old data lost.
2. Issue new Select/Read operation to
read dataIssue new CSTART
to
start new conversion.
3. Reconfigure the device.
01 1. Read FIFOSelect ChannelStart
new conversion. Channel must be
selected after FIFO READ.
2. Select ChannelStart new
conversion (old data lost)
3. Configure device again.
1. Read FIFOSelect ChannelStart
new conversion. Channel must be
selected after FIFO READ.
2. Select ChannelStart new
conversion (old data lost)
3. Configure device again.
1. Read FIFOSelect channelStart
new conversion. Channel must be
selected after FIFO READ.
2. Start new conversion (old data lost)
with existing setting.
3. Configure device again.
10 1. Read FIFOStart new conversion
with existing setting.
2. Configure deviceNew conversion
(old data lost)
1. Read FIFOStart new conversion
with existing setting.
2. Configure deviceNew conversion
(old data lost)
1. Read FIFOArm PeriodStart new
conversion with existing setting
2. Configure deviceArm PeriodNew
conversion (old data lost)
11 1. Read FIFOStart new conversion
with existing setting.
2. Start new conversion with the existing
setting.
3. Configure deviceStart new
conversion with new setting.
1. Read FIFOStart new conversion
with existing setting
2. Start new conversion with the existing
setting.
3. Configure DeviceStart new
conversion with new setting.
1. Read FIFOArm PeriodStart new
Conversion with existing setting
2. Start new conversion with existing
setting. (old data lost)
3. Configure deviceArm PeriodNew
conversion with new setting.
operation timing diagrams
The FIFO read and write CFR are nonconversion operations. The conversion operation performs one of four
types of conversion: mode 00, 01, 10, and 11
Write Cycle (WRITE CFR Command): Write cycle does not generate EOC or INT
, nor does it carry out any
conversion.
1
2
3
5
4
6
7
13 14 15 16
1
ID15 1D14 ID13 1D12
12
ID15ID11 ID10 ID9 ID4 ID3 ID2 ID1 ID0
OR
CS
FS
SDI
INT
EOC
SDO
Hi-Z
Note: Signal May Not Exist.
Dont Care
Figure 9. Write Cycle, FS Initiates Operation