Datasheet


******
TM
SLCS016ASEPTEMBER 1985 − REVISED SEPTEMBER 2002
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3
recommended operating conditions
TLC352C TLC352I
UNIT
MIN MAX MIN MAX
UNIT
Supply voltage, V
DD
1.4 16 1.4 16 V
Common-mode input voltage, V
IC
V
DD
= 5 V 0 3.5 0 3.5
V
Common-mode input voltage, V
IC
V
DD
= 10 V 0 8.5 0 8.5
V
Operating free-air temperature, T
A
0 70 − 40 85 °C
electrical characteristics at specified free-air temperature, V
DD
= 1.4 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
T
A
TLC352C TLC352I
UNIT
PARAMETER
TEST CONDITIONS
T
A
MIN TYP MAX MIN TYP MAX
UNIT
V
IO
Input offset voltage
V
IC
= V
ICR
min,
See Note 4
25°C 2 5 2 5
mV
V
IO
Input offset voltage V
IC
= V
ICR
min
,
See Note 4
Full range
6.5 7
mV
I
IO
Input offset current
25°C 1 1 pA
I
IO
Input offset current
MAX 0.3 1 nA
I
IB
Input bias current
25°C 5 5 pA
I
IB
Input bias current
MAX 0.6 2 nA
V
ICR
Common-mode input voltage range Full range
0 to
0.2
0 to
0.2
V
V
OL
Low-level output voltage
25°C 100 200 100 200
mV
V
OL
Low-level output voltage
Full range 200 200
mV
I
OL
Low-level output current V
ID
= − 0.5 V, V
OL
= 0.3 V 25°C 1 1.6 1 1.6 mA
I
DD
Supply current (two comparators)
V
ID
= 0.5 V,
No load
25°C 65 150 65 150
µA
DD
ID
Full range 200 200
µ
All characteristics are measured with zero common-mode input voltage unless otherwise noted. Full range is 0°C to 70°C for TLC352C, − 40°C to 85°C for TLC352I. IMPORTANT:
See Parameter Measurement Information.
NOTE 4: The offset voltage limits given are the maximum values required to drive the output above 1.25 V or below 150 mV with a 10-k resistor between the output and V
DD
. They
can be verified by applying the limit value to the input and checking for the appropriate output state.