Datasheet
SLOS051E − OCTOBER 1987 − REVISED AUGUST 2008
10
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics at specified free-air temperature, V
DD
= 10 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
T
A
†
TLC27M2M
TLC27M7M
UNIT
PARAMETER
TEST CONDITIONS
T
A
†
MIN TYP MAX
UNIT
TLC27M2M
V
O
= 1.4 V,
V
IC
= 0,
25°C 1.1 10
V
IO
Input offset voltage
TLC27M2M
V
O
= 1.4 V,
R
S
= 50 Ω,
V
IC
= 0,
R
L
= 100 kΩ
Full range
12
mV
V
IO
Input offset voltage
TLC27M7M
V
O
= 1.4 V,
V
IC
= 0,
25°C 190 800
mV
TLC27M7M
V
O
= 1.4 V,
R
S
= 50 Ω,
V
IC
= 0,
R
L
= 100 kΩ
Full range
4300
α
VIO
Average temperature coefficient of input
offset voltage
25°C to
125°C
2.1 µV/°C
I
IO
Input offset current (see Note 4)
V
O
= 5 V,
V
IC
= 5 V
25°C 0.1 60
pA
I
IO
Input offset current (see Note 4) V
O
= 5 V, V
IC
= 5 V
125°C
1.8 15
pA
I
IB
Input bias current (see Note 4)
V
O
= 5 V,
V
IC
= 5 V
25°C 0.7 60
pA
I
IB
Input bias current (see Note 4) V
O
= 5 V, V
IC
= 5 V
125°C
10 35
pA
V
ICR
Common-mode input voltage range
25°C
0
to
9
−0.3
to
9.2
V
V
ICR
Common-mode input voltage range
(see Note 5)
Full range
0
to
8.5
V
25°C 8 8.7
V
OH
High-level output voltage V
ID
= 100 mV, R
L
= 100 kΩ
−55°C
7.8 8.6
V
V
OH
High-level output voltage
V
ID
= 100 mV,
R
L
= 100 kΩ
125°C 7.8 8.8
V
25°C 0 50
V
OL
Low-level output voltage V
ID
= −100 mV, I
OL
= 0
−55°C
0 50
mV
V
OL
Low-level output voltage
V
ID
= −100 mV,
I
OL
= 0
125°C 0 50
mV
Large-signal differential voltage
25°C 25 275
A
VD
Large-signal differential voltage
amplification
V
O
= 1 V to 6 V, R
L
= 100 kΩ
−55°C
15 420
V/mV
A
VD
amplification
V
O
= 1 V to 6 V,
R
L
= 100 kΩ
125°C 15 190
V/mV
25°C 65 94
CMRR Common-mode rejection ratio V
IC
= V
ICR
min
−55°C 60 93
dB
CMRR
Common-mode rejection ratio
V
IC
= V
ICR
min
125°C 60 93
dB
Supply-voltage rejection ratio
25°C 70 93
k
SVR
Supply-voltage rejection ratio
(∆V
DD
/∆V
IO
)
V
DD
= 5 V to 10 V, V
O
= 1.4 V
−55°C
60 91
dB
k
SVR
(∆V
DD
/∆V
IO
)
V
DD
= 5 V to 10 V,
V
O
= 1.4 V
125°C 60 94
dB
V
O
= 5 V,
V
IC
= 5 V,
25°C 285 600
I
DD
Supply current (two amplifiers)
V
O
= 5 V,
No load
V
IC
= 5 V,
−55°C
490 1000
µA
I
DD
Supply current (two amplifiers)
No load
125°C 180 480
µA
†
Full range is −55°C to 125°C.
NOTES: 4. The typical values of input bias current and input offset current below 5 pA were determined mathematically.
5. This range also applies to each input individually.