Datasheet

SLOS019E − SEPTEMBER 1988 − REVISED FEBRUARY 2005
8
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
operating characteristics at specified free-air temperature, V
DD±
= ±5 V
PARAMETER
TEST
T
A
†
TLC2652I TLC2652AI
UNIT
PARAMETER
TEST
CONDITIONS
T
A
†
MIN TYP MAX MIN TYP MAX
UNIT
SR+
Positive slew rate at unity gain
V = 2.3 V,
25°C 2 2.8 2 2.8
V/ s
SR+ Positive slew rate at unity gain
V
O
= ±2.3 V,
R
L
= 10 kΩ,
Full range 1.4 1.4
V/µs
SR−
Negative slew rate at unity gain
O
R
L
= 10 k
Ω
,
C
L
= 100 pF
25°C 2.3 3.1 2.3 3.1
V/ s
SR− Negative slew rate at unity gain
C
L
= 100 pF
Full range 1.7 1.7
V/µs
V
n
Equivalent input noise voltage
f = 10 Hz 25°C 94 94 140
nV/√Hz
V
n
Equivalent input noise voltage
(see Note 6)
f = 1 kHz
25°C 23 23 35
nV/√Hz
V
N(PP)
Peak-to-peak equivalent input
f = 0 to 1 Hz 25°C 0.8 0.8
V
V
N(PP)
Peak-to-peak equivalent input
noise voltage
f = 0 to 10 Hz
25°C 2.8 2.8
µV
I
n
Equivalent input noise current f = 1 kHz 25°C 0.004 0.004 pA/√Hz
f = 10 kHz,
Gain-bandwidth product
f = 10 kHz,
R
L
= 10 kΩ,
25
°
C
1.9
1.9
MHz
Gain-bandwidth product
R
L
= 10 kΩ,
C
L
= 100 pF
25 C
1.9
1.9
MHz
φm
Phase margin at unity gain
R
L
= 10 kΩ,
C
L
= 100 pF
25°C 48° 48°
†
Full range is −40° to 85°C.
NOTE 6: This parameter is tested on a sample basis for the TLC2652A. For other test requirements, please contact the factory. This statement
has no bearing on testing or nontesting of other parameters.