Datasheet
TAS5414A, TAS5424A
www.ti.com
SLOS535C –MAY 2009– REVISED APRIL 2011
Table 6. Fault Register 2 (0x01) Protection (continued)
D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION
– – – – – 1 – – Overcurrent shutdown channel 3 has occurred
– – – – 1 – – – Overcurrent shutdown channel 4 has occurred
– – – 1 – – – – DC offset channel 1 has occurred
– – 1 – – – – – DC offset channel 2 has occurred
– 1 – – – – – – DC offset channel 3 has occurred
1 – – – – – – – DC offset channel 4 has occurred
Table 7. Diagnostic Register 1 (0x02) Load Diagnostics
D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION
0 0 0 0 0 0 0 0 No load-diagnostic-created faults, default value
– – – – – – – 1 Output short to ground channel 1 has occurred
– – – – – – 1 – Output short to PVDD channel 1 has occurred
– – – – – 1 – – Shorted load channel 1 has occurred
– – – – 1 – – – Open load channel 1 has occurred
– – – 1 – – – – Output short to ground channel 2 has occurred
– – 1 – – – – – Output short to PVDD channel 2 has occurred
– 1 – – – – – – Shorted load channel 2 has occurred
1 – – – – – – – Open load channel 2 has occurred
Table 8. Diagnostic Register 2 (0x03) Load Diagnostics
D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION
0 0 0 0 0 0 0 0 No load-diagnostic-created faults, default value
– – – – – – – 1 Output short to ground channel 3 has occurred
– – – – – – 1 – Output short to PVDD channel 3 has occurred
– – – – – 1 – – Shorted load channel 3 has occurred
– – – – 1 – – – Open load channel 3 has occurred
– – – 1 – – – – Output short to ground channel 4 has occurred
– – 1 – – – – – Output short to PVDD channel 4 has occurred
– 1 – – – – – – Shorted load channel 4 has occurred
1 – – – – – – – Open load channel 4 has occurred
Table 9. External Status Register 1 (0x04) Fault Detection
D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION
0 0 0 0 0 0 0 0 No protection-created faults are present, default value
– – – – – – – 1 PVDD overvoltage fault is present
– – – – – – 1 – PVDD undervoltage fault is present
– – – – – 1 – – AVDD, analog voltage fault is present
– – – – 1 – – – Charge-pump voltage fault is present
– – – 1 – – – – Overtemperature shutdown is present
– – 1 – – – – – Overtemperature warning
– 1 1 – – – – – Overtemperature warning level 1
1 0 1 – – – – – Overtemperature warning level 2
1 1 1 – – – – – Overtemperature warning level 3
Copyright © 2009–2011, Texas Instruments Incorporated 25