Datasheet
TLC226x, TLC226xA
Advanced LinCMOS RAIL-TO-RAIL
OPERATIONAL AMPLIFIERS
SLOS177D – FEBRUARY 1997 – REVISED MARCH 2001
40
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
TYPICAL CHARACTERISTICS
Figure 36
100
95
90
KSVR – Supply-Voltage Rejection Ratio – dB
105
SUPPLY-VOLTAGE REJECTION RATIO
†
vs
FREE-AIR TEMPERATURE
110
–50 –25 0 25 50 75 100 125
k
SVR
T
A
– Free-Air Temperature – °C
V
O
= 0
V
DD±
= ±2.2 V to ±8 V
–75
Figure 37
300
200
100
0
012345
IDD – Supply Current – uA
400
500
600
678
| V
DD±
| – Supply Voltage – V
T
A
= 25°C
T
A
= 125°C
T
A
= –55°C
V
O
= 0
No Load
I
DD
Aµ
T
A
= 40°C
TLC2262
SUPPLY CURRENT
†
vs
SUPPLY VOLTAGE
Figure 38
600
400
200
0
012345
IDD – Supply Current – uA
800
1000
1200
678
| V
DD±
| – Supply Voltage – V
T
A
= 25°C
T
A
= 125°C
T
A
= –55°C
V
O
= 0
No Load
I
DD
Aµ
T
A
= 40°C
TLC2264
SUPPLY CURRENT
†
vs
SUPPLY VOLTAGE
Figure 39
300
200
100
0
400
500
600
–75 –50 –25 0 25 50 75 100
IDD – Supply Current – uA
I
DD
Aµ
T
A
– Free-Air Temperature – °C
V
DD±
= ±5 V
V
O
= 0
V
DD
= 5 V
V
O
= 2.5 V
125
TLC2262
SUPPLY CURRENT
†‡
vs
FREE-AIR TEMPERATURE
†
Data at high and low temperatures are applicable only within the rated operating free-air temperature ranges of the various devices.
‡
For curves where V
DD
= 5 V, all loads are referenced to 2.5 V.