Datasheet

   
   
 
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
15
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
TLC2202C electrical characteristics at specified free-air temperature, V
DD±
= ±5 V (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
T
A
TLC2202AC TLC2202BC
UNIT
PARAMETER
TEST CONDITIONS
T
A
MIN TYP MAX MIN TYP MAX
UNIT
V
IO
Input offset voltage
25°C 80 500 80 500
µV
V
IO
Input offset voltage
Full range 650 650
µ
V
α
VIO
Temperature coefficient
of input offset voltage
Full range
0.5
0.5
µV/°C
α
VIO
Temperature coefficient
of input offset voltage
Full range
0.5
0.5
µ
V/
°
C
Input offset voltage long-term
drift (see Note 4)
V
IC
= 0, R
S
= 50
25°C
0.001 0.005 0.001 0.005 µV/mo
I
IO
Input offset current
25°C 0.5 60 0.5 60
pA
I
IO
Input offset current
Full range 100 100
pA
I
IB
Input bias current
25°C 1 60 1 60
pA
I
IB
Input bias current
Full range 100 100
pA
Common-mode input voltage
−5
−5
V
ICR
Common-mode input voltage
range
R
S
= 50 Full range
−5
to
−5
to
V
V
ICR
range
R
S
= 50
Full range
to
2.7
to
2.7
V
V
OM+
Maximum positive peak
output voltage swing
25°C 4.7 4.8 4.7 4.8
V
V
OM+
Maximum positive peak
output voltage swing
R
L
= 10 k
Full range 4.7 4.7
V
V
OM
Maximum negative peak
output voltage swing
R
L
= 10 k
25°C 4.7 4.9 4.7 4.9
V
V
OM
Maximum negative peak
output voltage swing
Full range 4.7 4.7
V
V
O
= ±4 V,
R
L
= 500 k
25°C 300 560 300 560
A
VD
Large-signal differential
voltage amplification
V
O
=
±
4 V,
R
L
= 500 k
Full range
200 200
V/mV
A
VD
Large-signal differential
voltage amplification
V
O
= ±4 V,
R
L
= 10 k
25°C 50 100 50 100
V/mV
voltage amplification
V
O
=
±
4 V,
R
L
= 10 k
Full range
25 25
CMRR
Common-mode rejection ratio
V
IC
= V
ICR
min,
V = 0, R = 50
25°C 80 115 80 115
dB
CMRR
Common-mode rejection ratio
V
IC
= V
ICR
min,
V
O
= 0, R
S
= 50
Full range 80 80
dB
k
SVR
Supply-voltage rejection ratio
( V / V)
V
DD
= ±2.3 V to ±8 V
25°C 80 110 80 110
dB
k
SVR
Supply-voltage rejection ratio
(V
DD±
/V
IO
)
V
DD±
=
±
2.3 V to
±
8 V
Full range 80 80
dB
I
DD
Supply current
V
O
= 0,
No load
25°C 1.8 2.7 1.8 2.7
mA
I
DD
Supply current
V
O
= 0,
No load
Full range 2.7 2.7
mA
Full range is 0°C to +70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at T
A
= 150°C extrapolated
to T
A
= 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2202C operating characteristics at specified free-air temperature, V
DD±
= ±5 V
PARAMETER
TEST CONDITIONS
T
A
TLC2202AC TLC2202BC
UNIT
PARAMETER
TEST CONDITIONS
T
A
MIN TYP MAX MIN TYP MAX
UNIT
V
O
= ±2.3 V,
25°C
1.8
2.7
1.8
2.7
SR
Slew rate at unity gain
V
O
=
±
2.3 V,
25
°
C
1.8
2.7
1.8
2.7
V/ s
SR Slew rate at unity gain
V
O
= ±2.3 V,
R
L
= 10 k,C
L
= 100 pF
Full range 1.3 1.3
V/µs
V
n
Equivalent input noise voltage
(see Note 5)
f = 10 Hz 25°C 18 35 18 30
nV/Hz
V
n
Equivalent input noise voltage
(see Note 5)
f = 1 kHz
25°C 8 15 8 12
nV/Hz
V
N(PP)
Peak-to-peak equivalent input
noise voltage
f = 0.1 to 1 Hz 25°C 0.5 0.5
µV
V
N(PP
)
Peak-to-peak equivalent input
noise voltage
f = 0.1 to 10 Hz
25°C 0.7 0.7
µ
V
I
n
Equivalent input noise current 25°C 0.6 0.6
fA/Hz
Gain-bandwidth product
f = 10 kHz, R
L
= 10 k
25 C
1.9
1.9
MHz
Gain-bandwidth product
f = 10 kHz, R
L
= 10 k
,
C
L
= 100 pF
25
°
C
1.9
1.9
MHz
Gain-bandwidth product
L
C
L
= 100 pF
25 C
1.9
1.9
MHz
φ
m
Phase margin at unity gain
R
L
= 10 k,C
L
= 100 pF
25°C
48°
48°
φ
m
Phase margin at unity gain
R
L
= 10 k
,C
L
= 100 pF
25
°
C
48
°
48
°
Full range is 0°C to +70°C.
NOTE 5: This parameter is tested on a sample basis for the TLC2202A and on all devices for the TLC2202B. For other test requirements, please
contact the factory. This statement has no bearing on testing or nontesting of other parameters.