Datasheet

TLC1514, TLC1518
5-V, 10-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER,
SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN
SLAS252 – DECEMBER 1999
10
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
timing diagrams
The timing diagrams can be categorized into two major groups: nonconversion and conversion. The
nonconversion cycles are read and write (configuration). None of these cycles carry a conversion. The
conversion cycles are the four modes shown in Figure 7 through Figure 14.
read cycle (read FIFO or read CFR)
read CFR cycle:
The read command is decoded in the first 4 clocks. SDO outputs the contents of the CFR after the 4th SCLK.
SCLK
CS
FS
SDI
INT
EOC
SDO
ID14 ID13 ID12 ID15
OD11 OD10 OD9 OD4 OD3 OD2 OD1 OD0
12 345 6
7131415
16
1
12
ID15
Command
Register Data
Figure 2. TLC1514/TLC1518 Read CFR Cycle (FS active)
SCLK
CS
FS
SDI
INT
EOC
SDO
ID15 ID14 ID13 ID12 ID14
OD4 OD3 OD2 OD1 OD0
12 345 6
7131415
16
1
12
OD11 OD10 OD9
ID15
Command
Register Data
Figure 3. TLC1514/TLC1518 Read CFR Cycle (FS = 1)