Datasheet

TLC080 , TLC081, TLC082
TLC083, TLC084, TLC085, TLC08xA
SLOS254F JUNE 1999REVISED DECEMBER 2011
www.ti.com
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
(1)
VALUE UNIT
Supply voltage, V
DD
(2)
17 V
Differential input voltage range, V
ID
±VDD
Continuous total power dissipation See Dissipation Rating Table
C suffix 0 to 70 °C
Operating free-air temperature range, T
A
:
I suffix 40 to 125 °C
Maximum junction temperature, T
J
150 °C
Storage temperature range, T
stg
65 to 150 °C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260 °C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential voltages, are with respect to GND .
DISSIPATION RATING TABLE
θ
JC
θ
JA
T
A
25°C
PACKAGE
(°C/W) (°C/W) POWER RATING
D (8) 38.3 176 710 mW
D (14) 26.9 122.3 1022 mW
D (16) 25.7 114.7 1090 mW
DGN (8) 4.7 52.7 2.37 W
DGQ (10) 4.7 52.3 2.39 W
N (14, 16) 32 78 1600 mW
P (8) 41 104 1200 mW
PWP (20) 1.40 26.1 4.79 W
RECOMMENDED OPERATING CONDITIONS
MIN MAX UNIT
Single supply 4.5 16
Supply voltage, V
DD
V
Split supply ±2.25 ±8
Common-mode input voltage, V
ICR
GND V
DD
2 V
V
IH
2
Shutdown on/off voltage level
(1)
V
V
IL
0.8
C-suffix 0 70
Operating free-air temperature, T
A
°C
I-suffix 40 125
(1) Relative to the voltage on the GND terminal of the device.
4 Submit Documentation Feedback Copyright © 19992011, Texas Instruments Incorporated
Product Folder Link(s): TLC080 TLC081 TLC082 TLC083 TLC084 TLC085 TLC08xA