TLC0834C, TLC0834I, TLC0838C, TLC0838I
8-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL
SLAS094E – MARCH 1995 – REVISED OCTOBER 2000
8
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended range of operating free-air temperature, V
CC
= 5 V,
f
(clock)
= 250 kHz (unless otherwise noted) (continued)
analog and converter section
PARAMETER TEST CONDITIONS
MIN TYP
MAX UNIT
0.05
V
IC
Common-mode input voltage See Note 3
to
V
IC
g
V
CC
+0.05
On channel V
I
= 5 V 1
I
I( tdb )
Standby in
p
ut current (see Note 4)
Off channel V
I
= 0 –1
µA
I
I(stdby)
Standb
y
inp
u
t
c
u
rrent
(see
Note
4)
On channel V
I
= 0 –1
µ
A
Off channel V
I
= 5 V 1
r
i(REF)
Input resistance to REF 1.3 2.4 5.9 k
All parameters are measured under open-loop conditions with zero common-mode input voltage.
All typical values are at V
CC
= 5 V, T
A
= 25°C.
NOTES: 3. When channel IN– is more positive than channel IN+, the digital output code is 0000 0000. Connected to each analog input are
two on-chip diodes that conduct forward current for analog input voltages one diode drop above V
CC
.Care must be taken during
testing at low V
CC
levels (4.5 V) because high-level analog input voltage (5 V) can, especially at high temperatures, cause the input
diode to conduct and cause errors for analog inputs that are near full scale. As long as the analog voltage does not exceed the supply
voltage by more than 50 mV, the output code is correct. To achieve an absolute 0- to 5-V input range requires a minimum V
CC
of
4.950 V for all variations of temperature and load.
4. Standby input currents go in or out of the on or off channels when the A/D converter is not performing conversion and the clock is
in a high or low steady-state condition.
total device
PARAMETER MIN TYP
MAX UNIT
I
CC
Supply current 0.6 1.25 mA
All typical values are at V
CC
= 5 V, T
A
= 25°C.
operating characteristics, V
CC
= 5 V, f
(clock)
= 250 kHz, t
r
= t
f
= 20 ns, T
A
= 25°C (unless otherwise
noted)
PARAMETER TEST CONDITIONS
§
MIN TYP MAX UNIT
Supply-voltage variation error V
CC
= 4.75 V to 5.25 V ±1/16 ±1/4 LSB
Total unadjusted error (see Note 5) V
ref
= 5 V, T
A
= MIN to MAX ±1 LSB
Common-mode error Differential mode ±1/16 ±1/4 LSB
t
d
Propagation delay time, output
MSB-first data
C
L
= 100
p
F
1500
ns
t
pd
gy,
data after CLK (see Note 6 and Figure 2)
LSB-first data
C
L
=
100
pF
600
ns
t
di
Output disable time DO or SARS after CS(see Figure 3)
C
L
= 10 pF, R
L
= 10 k 250
ns
t
dis
O
u
t
pu
t
di
sa
bl
e
ti
me,
DO
or
SARS
a
ft
er
CS(
see
Fi
gure
3)
C
L
= 100 pF, R
L
= 2 k 500
ns
t
c
Conversion time (multiplexer-addressing time not included) 8
clock
periods
§
All parameters are measured under open-loop conditions with zero common-mode input voltage. For conditions shown as MIN or MAX, use the
appropriate value specified under recommended operating conditions.
NOTES: 5. Total unadjusted error includes offset, full-scale, linearity, and multiplexer errors.
6. The MSB-first data is output directly from the comparator and, therefore, requires additional delay to allow for comparator response
time.