Datasheet

TL971, TL972, TL974
www.ti.com
SLOS467G OCTOBER 2006REVISED MAY 2012
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
V
CC
Supply voltage range
(2)
2.7 V to 15 V
V
ID
Differential input voltage
(3)
±1 V
V
IN
Input voltage range
(4)
V
CC–
– 0.3 V to V
CC+
+ 0.3 V
8 pin 97°C/W
D package
(5)
14 pin 86°C/W
DBV package
(5)
206°C/W
DGK package
(6)
172°C/W
θ
JA
Package thermal impedance, junction to free air DRG package
(6)
44°C/W
N package
(5)
80°C/W
P package
(5)
85°C/W
8 pin 149°C/W
PW package
(5)
14 pin 113°C/W
T
J
Maximum junction temperature 150°C
T
stg
Storage temperature range –65°C to 150°C
Human-Body Model (HBM) 2000 V
ESD Electrostatic discharge protection Machine Model (MM) 200 V
Charged-Device Model (CDM) 1500 V
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential voltages, are with respect to network ground terminal.
(3) Differential voltages for the noninverting input terminal are with respect to the inverting input terminal.
(4) The input and output voltages must never exceed V
CC
+ 0.3 V.
(5) Package thermal impedance is calculated in accordance with JESD 51-7.
(6) Package thermal impedance is calculated in accordance with JESD 51-5.
RECOMMENDED OPERATING CONDITIONS
MIN MAX UNIT
V
CC
Supply voltage 2.7 12 V
V
ICM
Common-mode input voltage V
CC–
+ 1.15 V
CC+
– 1.15 V
T
A
Operating free-air temperature –40 125 °C
Copyright © 2006–2012, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): TL971 TL972 TL974