Datasheet

TL7770-5, TL7770-12
DUAL POWER-SUPPLY SUPERVISORS
SLVS019F – OCTOBER 1987 – REVISED JULY 1999
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
timing requirements
RESET
V
IT–
VSU
V
IT+
V
CC
= 1 V (TYP)
V
OH
V
OL
Undefined Operation
for V
CC
Less Than 1 V
V
OL
V
OH
V
T
VSO
SCR DRIVE
t
d
t
d
t
d
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
(see Note 1) 20 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
: 1VSU, 2VSU, 1VSO, and 2VSO (see Note 1) –0.3 V to 18 V. . . . . . . . . . . . . . . . . . . .
Low-level output current (1RESET
and 2RESET), I
OL
20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High-level output current (1RESET and 2RESET), I
OH
–20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θ
JA
(see Notes 2 and 3): DW package 57°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . .
N package 88°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 in) from case for 10 seconds: DW or N package 260°C. . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to the network ground terminal.
2. Maximum power dissipation is a function of T
J
(max),
θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable
ambient temperature is P
D
= (T
J
(max) – T
A
)/
θ
JA
. Operating at the absolute maximum T
J
of 150°C can impact reliability.
3. The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace
length of zero.