TL5001, TL5001A
PULSE-WIDTH-MODULATION CONTROL CIRCUITS
SLVS084F APRIL 1994 REVISED JANUARY 2002
7
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range, V
CC
= 6 V,
f
osc
= 100 kHz (unless otherwise noted)
reference
PARAMETER
TEST CONDITIONS
TL5001C, TL5001I TL5001AC, TL5001AI
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
MAX MIN TYP
MAX
UNIT
Output voltage COMP connected to FB 0.95 1 1.05 0.97 1 1.03 V
Input regulation V
CC
= 3.6 V to 40 V 2 12.5 2 12.5 mV
T
A
= 20°C to 25°C (C suffix) 10 1 10 10 1 10
Output voltage change with temperature
T
A
= 40°C to 25°C (I suffix) 10 1 10 10 1 10
mV/V
T
A
= 25°C to 85°C 10 2 10 10 2 10
All typical values are at T
A
= 25°C.
undervoltage lockout
PARAMETER
TEST CONDITIONS
TL5001C, TL5001I TL5001AC, TL5001AI
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
MAX MIN TYP
MAX
UNIT
Upper threshold voltage T
A
= 25°C 3 3 V
Lower threshold voltage T
A
= 25°C 2.8 2.8 V
Hysteresis T
A
= 25°C 100 200 100 200 mV
Reset threshold voltage T
A
= 25°C 2.1 2.55 2.1 2.55 V
All typical values are at T
A
= 25°C.
short-circuit protection
PARAMETER
TEST CONDITIONS
TL5001C, TL5001I TL5001AC, TL5001AI
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
MAX MIN TYP
MAX
UNIT
SCP threshold voltage T
A
= 25°C 0.95 1.00 1.05 0.97 1.00 1.03 V
SCP voltage, latched No pullup 140 185 230 140 185 230 mV
SCP voltage, UVLO standby No pullup 60 120 60 120 mV
Input source current T
A
= 25°C 10 15 20 10 15 20 µA
SCP comparator 1 threshold voltage 1.5 1.5 V
All typical values are at T
A
= 25°C.
oscillator
PARAMETER
TEST CONDITIONS
TL5001C, TL5001I TL5001AC, TL5001AI
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
MAX MIN TYP
MAX
UNIT
Frequency R
t
= 100 k 100 100 kHz
Standard deviation of frequency 15 15 kHz
Frequency change with voltage V
CC
= 3.6 V to 40 V 1 1 kHz
T
A
= 40°C to 25°C 4 0.4 4 4 0.4 4 kHz
Frequency change with temperature
T
A
= 20°C to 25°C 4 0.4 4 4 0.4 4 kHz
T
A
= 25°C to 85°C 4 0.2 4 4 0.2 4 kHz
Voltage at RT 1 1 V
All typical values are at T
A
= 25°C.