Datasheet

TL5001, TL5001A
PULSE-WIDTH-MODULATION CONTROL CIRCUITS
SLVS084F APRIL 1994 REVISED JANUARY 2002
11
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range, V
CC
= 6 V,
f
osc
= 100 kHz (unless otherwise noted) (continued)
output
PARAMETER TEST CONDITIONS
TL5001Q,
TL5001M
TL5001AQ,
TL5001AM
UNIT
MIN TYP
MAX MIN TYP
MAX
Output saturation voltage T
A
= MIN to MAX I
O
= 10 mA 1.5 2 1.5 2 V
Off state current
T
A
= MIN to MAX
V
O
= 50 V, V
CC
= 0 10 10
µA
Off
-
state
current
T
A
=
MIN
to
MAX
V
O
= 50 V 10 10
µ
A
Short-circuit output current T
A
= MIN to MAX V
O
= 6 V 40 40 mA
All typical values are at T
A
= 25°C.
total device
PARAMETER TEST CONDITIONS
TL5001Q,
TL5001M
TL5001AQ,
TL5001AM
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
MAX MIN TYP
MAX
UNIT
Standby supply current Off state T
A
= MIN to MAX 1 1.5 1 1.5 mA
Average supply current T
A
= MIN to MAX R
t
= 100 k 1.4 2.1 1.4 2.1 mA
All typical values are at T
A
= 25°C.