Datasheet
ABSOLUTE MAXIMUM RATINGS
DISSIPATION RATINGS
RECOMMENDED OPERATING CONDITIONS
TL5001A-Q1
SLVS603B – AUGUST 2005 – REVISED FEBRUARY 2009 ..............................................................................................................................................
www.ti.com
over operating free-air temperature range (unless otherwise noted)
(1)
V
CC
Supply voltage
(2)
41 V
V
I(FB)
Amplifier input voltage 20 V
V
O
Output voltage, OUT 51 V
I
O
Output current, OUT 21 mA
I
O(peak)
Output peak current, OUT 100 mA
Continuous total power dissipation See Dissipation Rating
T
A
Operating ambient temperature range, TL5001AQDRQ1 – 40 ° C to 125 ° C
T
stg
Storage temperature range – 65 ° C to 150 ° C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260 ° C
(1) Stresses beyond those listed under " absolute maximum ratings " may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under " recommended operating
conditions " is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to network ground terminal.
PACKAGE T
A
≤ 25 ° C DERATING FACTOR T
A
= 70 ° C T
A
= 85 ° C T
A
= 125 ° C
POWER RATING ABOVE T
A
= 25 ° C POWER RATING POWER RATING POWER RATING
D 725 mW 5.8 mW/ ° C 464 mW 377 mW 145 mW
MIN MAX UNIT
V
CC
Supply voltage 3.6 40 V
V
I(FB)
Amplifier input voltage 0 1.5 V
V
O
Output voltage, OUT 50 V
I
O
Output current, OUT 20 mA
COMP source current 45 µ A
COMP dc load resistance 100 k Ω
R
t
Oscillator timing resistor 15 250 k Ω
f
OSC
Oscillator frequency 20 500 kHz
T
A
Operating ambient temperature TL5001AQDRQ1 – 40 125 ° C
6 Submit Documentation Feedback Copyright © 2005 – 2009, Texas Instruments Incorporated
Product Folder Link(s): TL5001A-Q1