Datasheet
SLVS050D − JUNE 1976 − REVISED JANUARY 2005
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Regulator voltage (see Note 1) 30 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous regulator current 150 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θ
JA
(see Notes 2 and 3) 140°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature, T
J
150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to the anode terminal.
2. Maximum power dissipation is a function of T
J
(max),
θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable
ambient temperature is P
D
= (T
J
(max) − T
A
)/
θ
JA
. Operating at the absolute maximum T
J
of 150°C can impact reliability.
3. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions
MIN MAX UNIT
V
Z
Regulator voltage V
ref
30 V
I
Z
Regulator current 2 100 mA
T
A
Operating free-air temperature range TL430C 0 70 °C
electrical characteristics over recommended operating conditions, T
A
= 25°C (unless otherwise
noted)
PARAMETER
TEST
TEST CONDITIONS
TL430C
UNIT
PARAMETER
TEST
FIGURE
TEST CONDITIONS
MIN TYP MAX
UNIT
V
I(ref)
Reference input voltage 1 V
Z
= V
I(ref)
, I
Z
= 10 mA 2.5 2.75 3 V
αV
I(ref)
Temperature coefficient of reference input
voltage
1
V
Z
= V
I(ref)
,
T
A
= 0°C to 70°C
I
Z
= 10 mA,
120 ppm/°C
I
I(ref)
Reference input current 2
I
Z
= 10 mA,
R2 = ∞
R1 = 10 kΩ,
3 10 µA
I
ZK
Regulator current near lower knee of
regulation range
1 V
Z
= V
I(ref)
0.5 2 mA
I
ZK
Regulator current at maximum
1 V
Z
= V
I(ref)
50
mA
I
ZK
Regulator current at maximum
limit of regulation range
2
V
Z
= 5 V to 30 V, See Note 4 100
mA
r
z
Differential regulator resistance
(see Note 5)
1
V
Z
= V
I(ref),
∆I
Z
= (52 − 2) mA
1.5 3 Ω
V
Z
= 3 V 50
V
n
Noise voltage 2 f = 0.1 Hz to 10 Hz
V
Z
= 12 V 200
µV
V
n
Noise voltage
2
f = 0.1 Hz to 10 Hz
V
Z
= 30 V 650
µV
NOTES: 4. The average power dissipation, V
Z
• I
Z
• duty cycle, must not exceed the maximum continuous rating in any 10-ms interval.
5. The regulator resistance for V
Z
> V
I(ref)
, r
z
, is given by:
r
z
Ȁ+r
z
ǒ
1 )
R1
R2
Ǔ