Datasheet

Cathode and Load Currents
R
S
+
ǒ
V
S
* V
Z
Ǔ
(
I
L
) I
Z
)
(1)
TL4050
I
Z
+ I
L
I
L
I
Z
V
S
V
Z
R
S
TL4050
www.ti.com
........................................................................................................................................................ SLOS486A JUNE 2007 REVISED AUGUST 2009
In a typical shunt-regulator configuration (see Figure 3 ), an external resistor, R
S
, is connected between the
supply and the cathode of the TL4050. R
S
must be set properly, as it sets the total current available to supply the
load (I
L
) and bias the TL4050 (I
Z
). In all cases, I
Z
must stay within a specified range for proper operation of the
reference. Taking into consideration one extreme in the variation of the load and supply voltage (maximum I
L
and
minimum V
S
), R
S
must be small enough to supply the minimum I
Z
required for operation of the regulator, as
given by data-sheet parameters. At the other extreme, maximum V
S
and minimum I
L
, R
S
must be large enough
to limit I
Z
to less than its maximum-rated value of 15 mA.
R
S
is calculated according to Equation 1 :
Figure 3. Shunt Regulator
Copyright © 2007 2009, Texas Instruments Incorporated Submit Documentation Feedback 17
Product Folder Link(s): TL4050