Datasheet

CATHODE
ANODE
_
+
ABSOLUTE MAXIMUM RATINGS
(1)
RECOMMENDED OPERATING CONDITIONS
TL4050
www.ti.com
........................................................................................................................................................ SLOS486A JUNE 2007 REVISED AUGUST 2009
FUNCTIONAL BLOCK DIAGRAM
over free-air temperature range (unless otherwise noted)
MIN MAX UNIT
I
Z
Continuous cathode current 10 20 mA
DBV package 206
θ
JA
Package thermal impedance
(2) (3)
° C/W
DCK package 252
T
J
Operating virtual junction temperature 150 ° C
T
stg
Storage temperature range 65 150 ° C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) T
A
)/ θ
JA
. Operating at the absolute maximum T
J
of 150 ° C can affect reliability.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.
MIN MAX UNIT
I
Z
Cathode current
(1)
15 mA
I temperature 40 85
T
A
Free-air temperature ° C
Q temperature 40 125
(1) See parametric tables
Copyright © 2007 2009, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Link(s): TL4050