Datasheet


   
SLOS250G − JUNE 1999 − REVISED JANUARY 2005
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
recommended operating conditions
MIN MAX UNIT
V
CC
Single-supply voltage 3 30 V
V
CC+
Dual-supply voltage
1.5 15
V
V
CC−
Dual-supply voltage
−1.5 −15
V
T
A
Operating free-air temperature −40 125 °C
electrical characteristics at specified free-air temperature, V
CC
±
= ±15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
V
IO
Input offset voltage
See Note 6
25°C 2 10
mV
V
IO
Input offset voltage See Note 6
Full range 12
mV
a
V
IO
Temperature coefficient
of input offset voltage
See Note 6 Full range 10 µV/°C
I
IO
Input offset current
See Note 6
25°C 30 50
nA
I
IO
Input offset current See Note 6
Full range 200
nA
a
I
IO
Temperature coefficient
of input offset current
See Note 6 Full range 50 pA/°C
I
IB
Input bias current
See Note 6
25°C −200 −500
nA
I
IB
Input bias current See Note 6
Full range −800
nA
V
ICR
Common-mode input voltage range
25°C
V
CC−
to 13
V
CC−
to 13.5
V
R
L
= 10 k 25°C ±12 ±13.5
V
OM
Peak output-voltage swing
R
L
= 2 k
25°C ±10 ±13
V
V
OM
Peak output-voltage swing
R
L
= 2 k
Full range ±10
V
A
VD
Large-signal differential
V
O
= ±10 V,
R
L
= 2 k
25°C 20 200
V/mV
A
VD
Large-signal differential
voltage amplification
V
O
= ±10 V,
R
L
= 2 k
Full range
15
V/mV
B
OM
Maximum-output-swing bandwidth
V
OPP
= 20 V,
THD 5%,
A
VD
= 1,
R
L
= 2 k
25°C 9 kHz
B
1
Unity-gain bandwidth V
O
= 50 mV, R
L
= 10 k 25°C 1 MHz
φ
m
Phase margin C
L
= 200 pF, R
L
= 2 k 25°C 44 Deg
r
i
Input resistance f = 20 Hz 25°C 0.3 1 M
r
o
Output resistance f = 20 Hz 25°C 75
CMRR Common-mode rejection ratio V
IC
= V
ICR
(min) 25°C 70 90 dB
k
SVS
Supply-voltage sensitivity (V
IO
/V
CC
) V
CC±
= ±2.5 to ±15 V 25°C 30 150 µV/V
I
OS
Short-circuit output current
§
25°C ±10 ±30 ±55 mA
I
CC
Total supply current No load, See Note 6 25°C 0.7 2.8 mA
All characteristics are measured under open-loop conditions, with zero common-mode voltage, unless otherwise specified. Full range for T
A
is
−40°C to 125°C.
The V
ICR
limits are linked directly, volt-for-volt, to supply voltage; the positive limit is 2 V less than V
CC+
.
§
Temperature and/or supply voltages must be limited to ensure that the dissipation rating is not exceeded.
NOTE 6: V
IO
, I
IO
, I
IB
, and I
CC
are defined at V
O
= 0.