Datasheet
11.5 kΩ
124 Ω
200 kΩ
195 Ω
5.3 kΩ 5.7 kΩ 70 Ω 5.1 kΩ
pF
30
pF
30
2.1 k
Ω
2.12 kΩ
10.8 kΩ
40 Ω
ADJUSTMENT
OUTPUT
670 Ω
1.4 Ω
360 Ω
INPUT
310 Ω 5.6 kΩ251190 Ω310 Ω
TL317
www.ti.com
SLVS004H –APRIL 1979– REVISED OCTOBER 2011
SCHEMATIC
A. All component values shown are nominal.
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
(1)
VALUE UNIT
Input-to-output differential voltage, V
l
– V
O
35 V
D package 97 °C/W
LP package 140 °C/W
Package thermal impedance, θ
JA
(2)(3)
:
PS package 95 °C/W
PW package 149 °C/W
Operating virtual junction temperature, T
J
150 °C
Storage temperature range, T
stg
–65 to 150 °C
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) – T
A
)/θ
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.
RECOMMENDED OPERATING CONDITIONS
MIN MAX UNIT
V
I
– V
O
Input-to-output voltage differential 2.5 35 V
I
O
Output current 2.5 100 mA
TL317C 0 125 °C
T
J
Operating virtual-junction temperature
TL317 –20 125 °C
Copyright © 1979–2011, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): TL317