Datasheet

 
 
 
SLCS132C − MARCH 1997 − REVISED MAY 1997
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics, V
DD
= ±5 V, V
LE
= 0
PARAMETER
TEST CONDITIONS
TL3116C TL3116I
UNIT
PARAMETER
TEST CONDITIONS
MIN TYP MAX MIN TYP MAX
UNIT
V
I
= 100 mV,
T
A
= 25°C 9.9 12 9.9 12
t
pd1
Propagation delay time
V
I
= 100 mV,
V
OD
= 5 mV
T
A
= full range 9.9 14 9.9 15
ns
t
pd1
Propagation delay time
V
I
= 100 mV,
T
A
= 25°C 8.2 10.3 8.2 10.3
ns
V
I
= 100 mV,
V
OD
= 20 mV
T
A
= full range 8.2 12.7 8.2 13.7
t
sk(p)
Pulse skew (|t
pd+
− t
pd−
|)
V
I
= 100 mV,
T
A
= 25°C
V
OD
= 5 mV,
0.5 0.5 ns
t
su
Setup time, LATCH ENABLE 3.4 3.4 ns
Full range for the TL3116C is 0°C to 70°C. Full range for the TL3116I is −40°C to 85°C.
t
pd1
cannot be measured in automatic handling equipment with low values of overdrive. The TL3116 is 100% tested with a 1-V step and 500-mV
overdrive at T
A
= 25°C only. Correlation tests have shown that t
pd1
limits given can be ensured with this test, if additional dc tests are performed
to ensure that all internal bias conditions are correct. For low overdrive conditions, V
OS
is added to the overdrive.
TYPICAL CHARACTERISTICS
Table of Graphs
FIGURE
vs Input voltage 2
I
CC
Positive supply current
vs Frequency 3
I
CC
Positive supply current
vs Free-air temperature 4
I
CC
Negative supply current vs Free-air temperature 5
vs Overdrive voltage 6
vs Supply voltage 7
t
pd
Propagation delay time
vs Input impedance
8
t
pd
Propagation delay time
vs Load capacitance 9
vs Free-air temperature 10
V
IC
Common-mode input voltage vs Free-air temperature 11
V
IT
Input threshold voltage (LATCH ENABLE) vs Free-air temperature 12