Datasheet
SLLS165G − JANUARY 1994 − REVISED MARCH 2006
26
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
PRINCIPLES OF OPERATION
programmable baud rate generator (continued)
Table 8. Baud Rates Using an 1.8432-MHz Crystal
BAUD RATE
DESIRED
DIVISOR (N) USED TO
GENERATE 16× CLOCK
PERCENT ERROR DIFFERENCE
BETWEEN DESIRED AND ACTUAL
50 2304 —
75 1536 —
110 1047 0.026
134.5 857 0.058
150 768 —
300 384 —
600 192 —
1200 96 —
1800 64 —
2000 58 0.690
2400 48 —
3600 32 —
4800 24 —
7200 16 —
9600 12 —
19200 6 —
38400 3 —
56000 2 2.860
Table 9. Baud Rates Using an 3.072-MHz Crystal
BAUD RATE
DESIRED
DIVISOR (N) USED TO
GENERATE 16× CLOCK
PERCENT ERROR DIFFERENCE
BETWEEN DESIRED AND ACTUAL
50 3840 —
75 2560 —
110 1745 0.026
134.5 1428 0.034
150 1280 —
300 640 —
600 320 —
1200 160 —
1800 107 0.312
2000 96 —
2400 80 —
3600 53 0.628
4800 40 —
7200 27 1.230
9600 20 —
19200 10 —
38400 5 —