Terminal Functions (Continued)
TERMINAL
NAME
FN
NO.
PM
NO.
PN
NO.
I/O DESCRIPTION
RIA, RIB,
RIC
, RID
19, 30,
50, 63
18, 43,
58, 3
I Ring detect indicator. A low on RIx indicates the modem has received a ring signal from
the telephone line. The condition of this signal can be checked by reading bit 6 of the
modem-status register.
RTSA, RTSB,
RTSC
, RTSD
5, 13,
36, 44
26, 35,
66, 75
O Request to send. When active, RTS informs the modem or data set that the ACE is ready
to receive data. RTS
is set to the active level by setting the RTS modem-control register
bit, and is set to the inactive (high) level either as a result of a master reset, or during
loop-mode operations, or by clearing bit 1 (RTS) of the MCR. In the auto-RTS mode, RTS
is set to the inactive level by the receiver threshold-control logic.
RXA, RXB
RXC, RXD
7, 29,
41, 63
20, 29,
51, 62
17, 44,
57, 4
I Serial input. RXx is a serial-data input from a connected communications device. During
loopback mode, the RXx input is disabled from external connection and connected to the
TXx output internally.
RXRDY 38 54 O Receive ready. RXRDY goes low when the receive FIFO is full. It can be used as a single
transfer or multitransfer.
TXA, TXB
TXC, TXD
17, 19,
51, 53
8, 10,
39, 41
29, 32,
69, 72
O Transmit outputs. TXx is a composite serial-data output connected to a communications
device. TXA, TXB, TXC, and TXD are set to the marking (high) state as a result of reset.
TXRDY 39 55 O Transmit ready. TXRDY goes low when the transmit FIFO is full. It can be used as a single
transfer or multitransfer function.
V
CC
13, 30,
47, 64
21, 35,
52
5, 25,
45, 65
Power supply
XTAL1 35 25 50 I Crystal input 1 or external clock input. A crystal can be connected to XTAL1 and XTAL2 to
utilize the internal oscillator circuit. An external clock can be connected to drive the
internal-clock circuits.
XTAL2 36 26 51 O Crystal output 2 or buffered clock output (see XTAL1).
absolute maximum ratings over free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
(see Note 1) 0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range at any input, V
I
0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, V
O
0.5 V to V
CC
+ 3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total-power dissipation at (or below) 70°C 500 mW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: TL16C554A 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TL16C554AI −40°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .