Datasheet
SLLS185D − DECEMBER 1994 − REVISED JULY 2001
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
DRIVER SECTION
electrical characteristics over recommended operating free-air temperture range, V
DD
= 9 V,
V
SS
= −9 V, V
CC
= 5 V (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN
TYP
MAX UNIT
V
OH
High-level output voltage V
IL
= 0.8 V, R
L
= 3 kΩ, See Figure 1 6 7.5 V
V
OL
Low-level output voltage (see Note 3) V
IH
= 1.9 V, R
L
= 3 kΩ, See Figure 1 −7.5 −6 V
I
IH
High-level input current V
I
= 5 V, See Figure 2 10 µA
I
IL
Low-level input current V
I
= 0, See Figure 2 −1.6 mA
I
OS(H)
High-level short-circuit output current
(see Note 4)
V
IL
= 0.8 V, V
O
= 0 or V
SS
, See Figure 1 −4.5 −10 −19.5 mA
I
OS(L)
Low-level short-circuit output current V
IH
= 2 V, V
O
= 0 or V
DD
, See Figure 1 4.5 10 19.5 mA
r
O
Output resistance (see Note 5) V
CC
= V
DD
= V
SS
= 0, V
O
= −2 V to 2 V 300 Ω
NOTES: 3. The algebraic convention, where the more positive (less negative) limit is designated as maximum, is used in this data sheet for logic
levels only (e.g., if −10 V is maximum, the typical value is a more negative voltage).
4. Output short-circuit conditions must maintain the total power dissipation below absolute maximum ratings.
5. Test conditions are those specified by TIA/EIA-232-F and as listed above.
switching characteristics, V
CC
= 5 V, V
DD
= 12 V, V
SS
= −12 V, T
A
= 25°C
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
t
PLH
Propagation delay time, low- to high-level output R
L
= 3 kΩ to 7 kΩ, C
L
= 15 pF, See Figure 3 315 500 ns
t
PHL
Propagation delay time, high- to low-level output R
L
= 3 kΩ to 7 kΩ, C
L
= 15 pF, See Figure 3 75 175 ns
R
L
= 3 kΩ to 7 kΩ, C
L
= 15 pF, See Figure 3 60 100 ns
t
TLH
Transition time, low- to high-level output
R
L
= 3 kΩ to 7 kΩ, C
L
= 2500 pF,
See Figure 3 and Note 6
1.7 2.5 µs
R
L
= 3 kΩ to 7 kΩ, C
L
= 15 pF, See Figure 3 40 75 ns
t
THL
Transition time, high- to low-level output
R
L
= 3 kΩ to 7 kΩ, C
L
= 2500 pF,
See Figure 3 and Note 7
1.5 2.5 µs
NOTES: 6. Measured between −3-V and 3-V points of the output waveform (TIA/EIA-232-F conditions). All unused inputs are tied.
7. Measured between 3-V and −3-V points of the output waveform (TIA/EIA-232-F conditions). All unused inputs are tied.