Datasheet
TL103W, TL103WA
www.ti.com
SLOS437K –APRIL 2004–REVISED OCTOBER 2010
Absolute Maximum Ratings
(1)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage 36 V
V
ID
Operational amplifier input differential voltage 36 V
V
I
Operational amplifier input voltage range –0.3 36 V
I
KA
Voltage reference cathode current 100 mA
D package
(2) (3)
97
q
JA
Package thermal impedance °C/W
DRJ package
(2) (4)
TBD
T
J
Maximum junction temperature 150 °C
T
stg
Storage temperature range –65 150 °C
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability
(2) Maximum power dissipation is a function of T
J
(max), q
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) – T
A
)/q
JA
. Selecting the maximum of 150°C can affect reliability.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.
(4) The package thermal impedance is calculated in accordance with JESD 51-5.
Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
IN
Supply voltage 3 32 V
I
K
Cathode current 1 100 mA
T
A
Operating free-air temperature –40 105 °C
Copyright © 2004–2010, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): TL103W TL103WA