Datasheet
TL022C, TL022M
DUAL LOW-POWER OPERATIONAL AMPLIFIERS
SLOS076 – SEPTEMBER 1973 – REVISED SEPTEMBER 1990
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
schematic
Each Amplifier
Common to Both
Amplifiers
V
CC+
To Other
Amplifier
To Other Amplifier
V
CC–
IN–
IN+
OUT
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
TL022C TL022M UNIT
Supply voltage, V
CC+
(see Note 1) 18 22 V
Supply voltage, V
CC–
(see Note 1) –18 –22 V
Differential input voltage (see Note 2) ±30 ±30 V
Input voltage (any input, see Notes 1 and 3) ±15 ±15 V
Duration of output short circuit (see Note 4) unlimited unlimited
Continuous total dissipation See Dissipation Rating Table
Operating free-air temperature range 0 to 70 –55 to 125 °C
Storage temperature range –65 to 150 –65 to 150 °C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds JG or U package 300 °C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds D or P package 260 °C
NOTES: 1. All voltage values, unless otherwise noted, are with respect to the midpoint between V
CC+
and V
CC–
.
2. Differential voltages are at IN+ with respect to IN–.
3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
4. The output may be shorted to ground or either power supply. For the TL022M only, the unlimited duration of the short circuit applies
at (or below) 125°C case temperature or 75°C free-air temperature.
DISSIPATION RATING TABLE
PACKAGE
T
A
≤ 25°C
POWER RATING
DERATING
FACTOR
DERATE
ABOVE T
A
T
A
= 70°C
POWER RATING
T
A
= 125°C
POWER RATING
D 680 mW 5.8 mW/°C 33°C 464 mW —
JG 680 mW 8.4 mW/°C69°C 672 mW 210 mW
P 680 mW 8.0 mW/°C65°C 640 mW —
U 675 mW 5.4 mW/°C 25°C 432 mW 135 mW