Datasheet
PIN CONFIGURATION
SeeNotes
PowerPAD
TM
D4OUT
3
D3OUT
D1IN−
D4IN−
D2OUT
D2IN−
D3IN−
VS+
D1OUT
PWP Package
(TopView)
BIAS-2/D3D4
BIAS-1/D1D2
IADJ
D1IN+
D4IN+
GND
D2IN+
D3IN+
BIAS-1/D3D4
BIAS-2/D1D2
VS−
1
4
5
6
7
8
9
20
2
12
10
19
11
13
14
15
16
17
18
PowerPAD
T
M
1
2
3
4
5
6
7
19
18
17
16
15
14
13
8 9 10
11 12
24 23 22 21 20
D1IN+
D2IN+
GND
IADJ
BIAS-2/D3D4
BIAS-1/D3D4
VS+
NC
NC
NC
D3IN+
D4IN+
D1IN−
RHFPackage
(TopView)
D2IN−
D2OUT
D3OUT
D3IN−
D4IN−
D4OUT
BIAS-2/D1D2
BIAS-1/D1D2
VS−
NC
D1OUT
NC − Nointernalconnection
SeeNotes
RECOMMENDED OPERATING CONDITIONS
THS6184
www.ti.com
................................................................................................................................................. SLLS635D – AUGUST 2005 – REVISED JANUARY 2009
PACKAGING/ORDERING INFORMATION
(1)
PACKAGED DEVICES
(2)
DEVICE MARKING PACKAGE TYPE TRANSPORT MEDIA, QUANTITY
THS6184RHFT Tape and reel, 250
6184 QFN-24
THS6184RHFR Tape and reel, 3000
THS6184PWP Rails, 70
THS6184 PowerPAD™ HTSSOP-20
THS6184PWPR Tape and reel, 2000
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
website at www.ti.com .
(2) The thermal pad is electrically isolated from all other pins.
A. The THS6184 defaults to the FULL BIAS state if no signal is present on the BIAS pins.
B. The PowerPAD is electrically isolated from all other pins and can be connected to any potential voltage range from
V
S –
to V
S+
. Typically, the PowerPAD is connected to the GND plane as this plane tends to be physically the largest
and able to dissipate the most amount of heat.
C. The GND pin range is from V
S –
to (V
S+
– 2.5 V).
D. The I
ADJ
(RHF pin 4, PWP pin 6) must be connected to GND (RHF pin 3, PWP pin 5) for full bias as used in the
specification tables.
Over operating free-air temperature range (unless otherwise noted).
MIN MAX UNIT
Dual supply ± 4 ± 16
V
S –
to V
S+
Supply voltage V
Single supply 8 32
T
A
Operating free-air temperature – 40 85
° C
T
J
Operating junction temperature, continuous operating temperature – 40 130
Copyright © 2005 – 2009, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): THS6184