Datasheet
±
SLOS293D − JUNE 2000 − REVISED DECEMBER 2001
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range, T
A
= 25°C,
V
CC
= ±12 V, R
FEEDBACK
= 750 Ω, R
L
= 100 Ω (unless otherwise noted) (continued)
dc performance
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Input offset voltage
T
A
= 25°C 5 10
Input offset voltage
V
CC
= ±12 V,
T
A
= full range 15
mV
V
OS
Differential offset voltage
V
CC
= ±12 V,
V
CC
= ±6 V
T
A
= 25°C 3 6
mV
V
OS
Differential offset voltage
V
CC
= ±6 V
T
A
= full range 8
Offset drift T
A
= full range 30 µV/°C
− Input bias current
T
A
= 25°C 5 10
− Input bias current
T
A
= full range 12
I
IB
+ Input bias current
V
CC
=
±
12 V,
T
A
= 25°C 2 5
A
I
IB
+ Input bias current
V
CC
= ±12 V,
V
CC
= ±6 V
T
A
= full range 6
µA
Differential input bias current
V
CC
= 6 V
T
A
= 25°C 5 10
Differential input bias current
T
A
= full range 12
Z
OL
Open loop transimpedance
V
CC
= ±12 V, R
L
= 1 kΩ,
V
CC
= ±6 V
1 MΩ
input characteristics
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
ICR
Input common-mode voltage range
V
CC
= ±12 V ±9.7 ±10.1
V
V
ICR
Input common-mode voltage range
V
CC
= ±6 V
±3.8 ±4.2
V
CMRR
Common-mode rejection ratio
V
CC
=
±
12 V,
T
A
= 25°C 59 66
dB
CMRR
Common-mode rejection ratio
V
CC
= ±12 V,
V
CC
= ±6 V
T
A
= full range 57
dB
R
I
Input resistance
+ Input 1.5 MΩ
R
I
Input resistance
− Input
15 Ω
C
I
Input capacitance 2 pF
output characteristics
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
R
L
= 50 Ω, V
CC
= ± 6 V ±4.2 ±4.6
V
O
Output voltage swing Single ended
R
L
= 100 Ω
V
CC
= ±12 V ±10.1 ±10.5
V
V
O
Output voltage swing
Single ended
R
L
= 100
Ω
V
CC
= ±6 V ±4.4 ±4.8
V
I
O
Output current
R
L
= 25 Ω, V
CC
= ±12 V 150 175
mA
I
O
Output current
R
L
= 10 Ω, V
CC
= ±6 V 150 175
mA
I
SC
Short-circuit current R
L
= 0 Ω, V
CC
= ±12 V 250 mA
Output resistance Open loop 14 Ω