Datasheet

Shutdown Operation (Channels 1 and 2)
3-12
divider is formed by R26 and R27, taking the SD input to +V/2, which
disables the outputs of the EVM. Please note that due to the low-value
input and feedback resistors, some signal leaks from the inputs to the
outputs of the EVM.
Figure 3−10. Shutdown Operation
JP2
R25
+V
R26
TP5
SD
R27
SD
GND
NC
PWP
U1C
THS6043
5
6
7
8
9
10
15
100 W
4.99 kW
4.99 kW