3.2 Single Supply Operation
Many designs use single supply voltages, and the THS6043EVM allows single
supply operation. The THS6043EVM can be reconfigured for single supply
operation as shown in Figure 3−2. To convert to single supply operation:
- Connect ground from the power supply to both J5 (GND) and J4 (−V
CC
).
- Jumper pins 2 and 3 of JP1 together with a jumper plug. This enables
connection to a half supply voltage divider.
- Populate R4, R14, R20, and R21, with 4.99 k 1% resistors. R20 and R21
create the half supply potential (virtual ground for the stage). R4 and R14
sum this potential into the noninverting inputs of the op amps.
The half-supply virtual ground potential is also present on the
output of the op amps. No provision has been made on the EVM for
output dc-blocking capacitors. When the outputs are monitored
with equipment that has 50- inputs, 75 mW is dissipated through
R17, R18, and the input resistors of the measuring equipment.
- Remove the zero jumpers located at Z1 and Z2 and replace them with
dc-blocking capacitors.
Figure 3−2. Single-Supply Operation
+V
TP3
R4
R18
>>> GND
+
U1A
THS6043
2
3
1
14
4
R5
R17
Z2
J5
GND
R7
210
W
J2
IN2
R14
FB1
1
+V
TP4
OUT2
Z1
J1
IN1
J6
OUT1
JP1
R20
R1
TP1
+
C9
R23
0
+V
J3
+VCC
R21
R24
0
J4
−VCC
C3
J7
OUT2
FB2
+
U1B
THS6043
12
11
13
R12
V>>> GND
TP2
OUT1
R16
49.9 W
4.99 kW
4.99 kW
4.99 kW
0.1 mF
750 W
49.9 W
1 mF
4.99 kW
0.1 mF
49.9 W
750 W
1 mF
49.9 W