Input and Output Test Setup (See Figure 2−2)
2-3
Using the THS6043EVM
2.3 Input and Output Test Setup (See Figure 2−2)
- Set the function generator to a 1 MHz, ±2.5 V (5 V
pp
) sine wave with no
dc offset.
- Turn off the function generator before proceeding to the next step.
- Using a BNC cable, connect the function generator to J1 (IN1 BNC) on the
EVM.
- Using a BNC cable, connect the oscilloscope to J6 (OUT1 BNC) on the
EVM. Set the oscilloscope to 1 V/Division and a time base of 0.2 µSec/Divi-
sion. Note : The Oscilloscope must be set to 50-W termination for proper
operation.
Figure 2−2. Signal Connections