PARAMETER MEASUREMENT INFORMATION
+
–
1kW
V
I
V
O
50 W
50 W
1kW
Driver1
+
–
1kW
V
I
V
O
50 W
50 W
1kW
Driver2
S0284-01
V
I
V
O
+
–
R
G
R
F
R
L
50 W
50 W
V
CC–
V
CC+
S0285-01
THS6022
SLOS225D – SEPTEMBER 1998 – REVISED JULY 2007
ELECTRICAL CHARACTERISTICS (continued)
V
CC
= ± 15 V, R
L
= 50 Ω , R
F
= 1 k Ω , T
A
= 25 ° C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Output Characteristics
(4)
V
CC
= ± 5 ± 3 ± 3.2
single-ended R
L
= 50 Ω
V
CC
= ± 15 ± 12 ± 12.6
V
O
Output voltage swing V
V
CC
= ± 5 ± 6 ± 6.6
differential R
L
= 100 Ω
V
CC
= ± 15 ± 24.6 ± 25.2
V
CC
= ± 5 V, R
L
= 5 Ω 250
I
O
Output current
(5)
mA
V
CC
= ± 15, R
L
= 50 Ω 200 250
I
OS
Short-circuit output current
(6)
400 mA
R
O
Output resistance Open-loop 13 Ω
Power Supply
(4)
Split supply ± 4.5 ± 16.5
Power supply operating
V
CC
V
range
Single supply 9 33
T
A
= 25 ° C 6 8
V
CC
= ± 5
T
A
= full range 10
I
CC
Quiescent current (each driver) mA
T
A
= 25 ° C 7.2 9
V
CC
= ± 15
T
A
= full range 11
T
A
= 25 ° C –68 –76
V
CC
= ± 5 dB
T
A
= full range –65
PSRR Power-supply rejection ratio
T
A
= 25 ° C –64 –75
V
CC
= ± 15 dB
T
A
= full range –62
(4) Full range is 0 ° C to 70 ° C for the THS6022C, and –40 ° C to 85 ° C for the THS6022I.
(5) Slew rate is measured from an output level range of 25% to 75%.
(6) A heat sink is required to keep the junction temperature below absolute maximum when an output is heavily loaded or shorted. See the
absolute maximum ratings and Thermal Information section.
Figure 1. Input-to-Output Crosstalk Test Circuit
Figure 2. Test Circuit, Gain = 1 + (RF/RG)
7