Datasheet
SLOS388B − OCTOBER 2001 − REVISED JUNE 2002
8
www.ti.com
TYPICAL CHARACTERISTICS
measurement conditions: T
A
= 25°C, R
L
= 1 kΩ, V
S
= ±15 V (unless otherwise noted)
Figure 2
−8
−6
−4
−2
0
2
4
6
8
100 k 1 M 10 M 100 M 1 G
Gain − dB
Frequency − Hz
SMALL-SIGNAL UNITY GAIN
FREQUENCY RESPONSE
Gain = 1,
R
F
= 0Ω,
R
L
= 1 kΩ,
P
IN
= −30 dBm
Figure 3
−25
−20
−15
−10
−5
0
5
100 k 1 M 10 M 100 M
Gain − dB
LARGE-SIGNAL UNITY GAIN
FREQUENCY RESPONSE
Gain = 1,
R
F
= 0 Ω,
R
L
= 1 kΩ,
P
IN
= 0 dBm
Frequency − Hz
Figure 4
−10
−8
−6
−4
−2
0
2
4
6
8
10
100 k 1 M 10 M 100 M 1 G
Gain − dB
Frequency − Hz
SMALL-SIGNAL FREQUENCY RESPONSE,
GAIN = +2
Gain = 2,
R
F
= 62Ω,
R
L
= 1 kΩ,
P
IN
= −30 dBm
Figure 5
−15
−10
−5
0
5
10
15
20
100 k 1 M 10 M 100 M 1 G
Gain − dB
Frequency − Hz
SMALL-SIGNAL FREQUENCY RESPONSE,
GAIN = +5
Gain = 5,
R
F
= 500Ω,
R
L
= 1 kΩ,
P
IN
= −30 dBm
Figure 6
−15
−10
−5
0
5
10
15
20
25
100 k 1 M 10 M 100 M 1 G
Gain − dB
Frequency − Hz
SMALL-SIGNAL FREQUENCY RESPONSE,
GAIN = +10
Gain = 10,
R
F
= 1 kΩ,
R
L
= 1 kΩ,
P
IN
= −30 dBm
Figure 7
−10
0
10
20
30
40
50
100 k 1 M 10 M 100 M 1 G
Gain − dB
Frequency − Hz
SMALL-SIGNAL FREQUENCY RESPONSE,
GAIN = +100
Gain = 100,
R
F
= 5 kΩ,
R
L
= 1 kΩ,
P
IN
= −30 dBm