Datasheet
SLOS388B − OCTOBER 2001 − REVISED JUNE 2002
11
www.ti.com
TYPICAL CHARACTERISTICS
measurement conditions: T
A
= 25°C, R
L
= 1 kΩ, V
S
= ±15 V (unless otherwise noted)
Figure 20
−40
−35
−30
−25
−20
−15
−10
−5
0
5
10
15
−40 −20 0 20 40 60 80 100 120
Case Temperature − °C
Input Offset Current − pA
INPUT OFFSET CURRENT
vs
TEMPERATURE
Figure 21
0
0.50
1
1.50
2
2.50
−40 −20 0 20 40 60 80 100 120
Case Temperature − °C
Offset Voltage − mV
OFFSET VOLTAGE
vs
TEMPERATURE
Figure 22
9
9.2
9.4
9.6
9.8
10
10.2
−40 −20 0 20 40 60 80 100 120
Case Temperature − °C
Quiescent Current − mA
QUIESCENT CURRENT
vs
TEMPERATURE
Figure 23
40
45
50
55
60
65
70
75
80
85
90
−40 −20 0 20 40 60 80 100 120
Sourcing Current
Sinking Current
Case Temperature − °C
Output Current − mA
OUTPUT CURRENT
vs
TEMPERATURE
Figure 24
12.4
12.6
12.8
13
13.2
13.4
13.6
13.8
14
−40 −20 0 20 40 60 80 100 120
−14
−13.8
−13.6
−13.4
−13.2
−13
−12.8
−12.6
−12.4
Case Temperature − °C
Positive Output Voltage Sling − V
OUTPUT VOLTAGE SWING
vs
TEMPERATURE
Negative Output Voltage Swing − V
V
O
−
V
O
+
Figure 25
70
75
80
85
90
95
100
105
110
115
120
125
130
−40 −20 0 20 40 60 80 100 120
PSRR+
CMRR
PSRR−
Case Temperature − °C
Rejection Ratios − dB
REJECTION RATIOS
vs
TEMPERATURE