Datasheet

www.ti.com
ABSOLUTE MAXIMUM RATINGS
(1)
RECOMMENDED OPERATING CONDITIONS
THS4304
SLOS436A MARCH 2004 REVISED JULY 2004
over operating free-air temperature range (unless otherwise noted)
UNIT
V
S
Supply voltage +6.0 V
V
I
Input voltage ±V
S
I
O
Output current 150 mA
V
ID
Differential input voltage ±2 V
Continuous power dissipation See Dissipation Rating Table
Maximum junction temperature, any condition
(2)
150°C
T
J
Operating free-air temperature range, continuous operation, long-term reliability
(2)
125°C
T
stg
Storage temperature range –65°C to 150°C
Lead temperature: 1,6 mm (1/16 inch) from case for 10 seconds 300°C
HBM 1600 V
ESD Ratings CDM 1000 V
MM 100 V
(1) The absolute maximum ratings under any condition is limited by the constraints of the silicon process. Stresses above these ratings may
cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are
stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied.
(2) The maximum junction temperature for continuous operation is limited by package constraints. Operation above this temperature may
result in reduced reliability and/or lifetime of the device.
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
Dual supply ±1.35 ±2.5
Supply voltage, (V
S+
and V
S–
) V
Single supply 2.7 5
Input common-mode voltage range V
S–
0.2 V
S+
+ 0.2 V
3