Power-Down Reference Operation—THS4215EVM Only
3-4
Figure 3-4. Power-Down Reference Operation
R5
-
+
U1
THS4215
2
3
6
7
4 1
8
C7
J2
Vin+
R3
R4
J8
Vs+
R2
R6
C8
Vs-
J1
Vin-
J9
Power Down
R7
J4
Vout
392
0.1 F
453
49.9
0.1 F
49.9
Power-Down Ref
Note: This schematic reflects the default THS4215EVM configuration.
392
0
The reference pin allows the user to control the logic levels of the power-down
pin. The reference pin is mainly designed for systems with supply voltages
higher than 5 V; however, it works with any voltage within the amplifier’s
voltage range. In most cases, the reference pin is connected to a digital ground
or to ground. For example, a customer is using a 3-V microcontroller to control
the power-down pin of an amplifier that is operating from a ±5 V power supply.
Using the traditional power-down circuit, the customer has to buffer/boost the
3-V signal from the microcontroller to a higher level to ensure the proper
voltage level for the amplifier to toggle between enable and disable. With the
reference circuit, the customer can connect the 3-V signal directly to the
power-down pin.
When the reference pin is connected to ground, the power-down voltage
applied to the power-down pin must be greater than Ref +1.8 V (GND +1.8 V)
for the amplifier to be active (enable). To place the device into power-down
mode (disable) the voltage applied to the power-down pin must be less than
Ref +1 V (GND+1 V).
Now, when the reference pin is connected to the positive supply or allowed to
float, the power-down logic levels are referenced to the positive supply.
Therefore, if a system is operating on a split supply of 5 V and the reference
pin is left floating (not connected), the power-down pin voltage must be greater
than Ref –1 V (5 V–1; V = 4 V) for the amplifier to be active (enable). To place
the device into power-down mode (disable) the voltage applied to the
power-down pin must be less than Ref –1.5 V (5 V–1.5; V = 3.5 V).