Datasheet
SLOS274D − DECEMBER 1999 − REVISED JUNE 2001
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics at T
A
= 25°C, V
CC
= ±15 V, R
L
= 150 Ω (unless otherwise noted) (continued)
dc performance
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
CC
= ±15 V, V
O
= ±10 V, R
L
= 1 kΩ
T
A
= 25°C 10 19
V/mV
Open loop gain
V
CC
= ±15 V, V
O
= ±10 V, R
L
= 1 kΩ
T
A
= full range
†
9
V/mV
Open loop gain
V
CC
= ±5 V, V
O
= ±2.5 V, R
L
= 250 Ω
T
A
= 25°C 8 16
V/mV
V
CC
= ±5 V, V
O
= ±2.5 V, R
L
= 250 Ω
T
A
= full range
†
7
V/mV
V
OS
Input offset voltage
T
A
= 25°C 1 7
mV
V
OS
Input offset voltage
T
A
= full range
†
8
mV
Offset voltage drift T
A
= full range
†
15 µV/°C
I
IB
Input bias current
V
CC
= ±5 V or ±15 V
T
A
= 25°C 1.2 6
A
I
IB
Input bias current
V
CC
= ±5 V or ±15 V
T
A
= full range
†
8
µA
I
OS
Input offset current
T
A
= 25°C 20 250
nA
I
OS
Input offset current
T
A
= full range
†
400
nA
Offset current drift T
A
= full range
†
0.3 nA/°C
†
Full range = 0°C to 70°C for C suffix and −40°C to 85°C for I suffix
input characteristics
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
ICR
Common mode input voltage range
V
CC
= ±15 V ±13.8 ±14.1
V
V
ICR
Common mode input voltage range
V
CC
= ±5 V
±3.8 ±3.9
V
CMRR
Common mode rejection ratio
V
CC
= ±15 V, V
ICR
= ±12 V, T
A
= full range
†
78 90 dB
CMRR Common mode rejection ratio
V
CC
= ±5 V, V
ICR
= ±2 V,
T
A
= full range
†
84 93 dB
R
I
Input resistance 1 MΩ
C
I
Input capacitance 1.5 pF
†
Full range = 0°C to 70°C for C suffix and −40°C to 85°C for I suffix
output characteristics
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
CC
= ±15 V, R
L
= 250 Ω ±12 ±13.6
V
V
O
Output voltage swing
V
CC
= ±5 V, R
L
= 150 Ω ±3.4 ±3.8
V
V
O
Output voltage swing
V
CC
= ±15 V
R
L
= 1 kΩ
±13.5 ±13.8
V
V
CC
= ±5 V
R
L
= 1 kΩ
±3.5 ±3.9
V
I
O
Output current
V
CC
= ±15 V
R
L
= 20 Ω
65 85
mA
I
O
Output current
V
CC
= ±5 V
R
L
= 20 Ω
50 70
mA
I
SC
Short-circuit current
‡
V
CC
= ±15 V 100 mA
R
O
Output resistance Open loop 13 Ω
‡
Observe power dissipation ratings to keep the junction temperature below the absolute maximum rating when the output is heavily loaded or
shorted. See the absolute maximum ratings section of this data sheet for more information.